Venting Routed Through A Masonry Chimney - Trane UHMB060ACV3VA Installer's Manual

Upflow/ horizontal and downflow/ horizontal, gas-fired, direct vent, variable speed inducer, modulating condensing communicating furnaces
Hide thumbs Also See for UHMB060ACV3VA:
Table of Contents

Advertisement

,
.
PVC PLASTIC VENTING – ONLY
THROUGH UNUSED CHIMNEY
STAINLESS STEEL VENT CAP
(OPTIONAL)
STAINLESS
STEEL
VENT CAP
SEE CAUTION
FLUE PIPE
COUPLING TO SUPPORT
PIPE FROM ANGLES
OR OTHER SUITABLE
SUPPORT METHOD
FLUE PIPE
CAUTION
!
Do NOT run vent through chimney for wood burning
or oil Furnaces or incinerators or any other gas appli-
ance.
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be sealed
to prevent condensate leakage to base of masonry chim-
ney.
18-CD30D1-9
6 IN. MIN.
SUPPORT THE SINGLE
WALL FLUE PIPE AND
CENTER IT IN THE
CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
COUPLING
AS REQUIRED
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING
Installer's Guide
TYPE 29-4C STAINLESS STEEL VENTING –
/
USED THROUGH CHIMNEY THAT VENTS
ANOTHER GAS APPLIANCE
STAINLESS STEEL VENT
STAINLESS
CAP (OPTIONAL)
STEEL
VENT CAP
SEE CAUTION
CAUTION
!
Do NOT run vent through chimney for wood burning
or oil Furnaces or incinerators.
If remaining free area between single wall flue pipe
and masonry chimney is to be used for another gas
appliance venting area must be sufficient to vent that
appliance and that appliance must be connected to
chimney with separate entry openings.
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be sealed
to prevent condensate leakage to base of masonry chim-
ney.
6 IN. MIN.
SUPPORT THE SINGLE WALL
STAINLESS STEEL GAS
VENTING AND CENTER IT IN
THE CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING
27

Hide quick links:

Advertisement

Table of Contents
loading