Venting Routed Through A Masonry Chimney - Trane UX2B060AFV3VA Series Installer's Manual

Upflow/horizontal, gas-fired, direct vent, 2-stage condensing furnaces with variable speed inducer and whole house air cleaner
Table of Contents

Advertisement

Installer's Guide
Figure 23
PVC PLASTIC VENTING - ONLY
THROUGH UNUSED CHIMNEY
STAINLESS STEEL
STAINLESS
VENT CAP (OP-
STEEL
TIONAL)
VENT CAP
SEE CAUTION
FLUE PIPE
COUPLING TO SUPPORT
PIPE FROM ANGLES
OR OTHER SUITABLE
SUPPORT METHOD
FLUE PIPE
CAUTION
!
Do NOT run vent through chimney for wood burn-
ing or oil Furnaces or incinerators or any other gas
appliance.
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be
sealed to prevent condensate leakage to base of ma-
sonry chimney.
20
Figure 24
6 IN. MIN.
SUPPORT THE SINGLE
WALL FLUE PIPE AND
CENTER IT IN THE
CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
COUPLING
AS REQUIRED
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING

VENTING ROUTED THROUGH A MASONRY CHIMNEY

TYPE 29-4C STAINLESS STEEL VENTING - USED
THROUGH CHIMNEY THAT VENTS ANOTHER GAS
APPLIANCE
STAINLESS STEEL
STAINLESS
VENT CAP (OP-
STEEL
TIONAL)
VENT CAP
SEE CAUTION
CAUTION
!
Do NOT run vent through chimney for wood burning
or oil Furnaces or incinerators.
If remaining free area between single wall flue pipe
and masonry chimney is to be used for another gas
appliance venting area must be sufficient to vent that
appliance and that appliance must be connected to
chimney with separate entry openings.
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be
sealed to prevent condensate leakage to base of ma-
sonry chimney.
6 IN. MIN.
SUPPORT THE SINGLE WALL
STAINLESS STEEL GAS
VENTING AND CENTER IT IN
THE CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING
18-CD25D1-2