Installer's Guide
TABLE 20 - USER INTERFACE MENU - 24VOLT MENU (CONTINUED)
24V Variable Speed
System Status
CMFRT CNT MODE
COMM [24VAC] 24VAC
COOLING CFM 2
CFM PER TON
CLG STAGES
CLG 1ST STG CFM 3
CONT FAN CFM
FAN PRERUN DLY
FAN SHRTRUN DLY
FAN OFF DLY
HEAT CFM
HT OFF DELAY
W1 W2 STG DLY
FACTORY DEFLTS
EXIT
NOTES:
2 Shown only when Communicating Outdoor Unit is not detected
3 This menu will only display when 2 STGS is chosen in previous menu.
42
Setup Options
[ ] = Current Setting
COOLING CFM
*
CFM PER TON
400 [ 400 ] 430 450 290 310 330 350 370
CLG STAGES
1 STG [1 STG]
2 STGS
CLG 1ST STG CFM 2
50% [50%]
55%
65%
80%
CONT FAN CFM
50% [50%]
75%
100%
25%
FAN PRERUN DLY
NONE [NONE]
1m@50%
FAN SHRTRUN DLY
NONE [NONE]
4m@80%
7.5m@80%
FAN OFF DLY
1.5m@100% [1.5m@100%]
NONE
1m@50%
HEAT CFM
**
HT OFF DELAY
100s [100s] 140 180 60
W1 W2 STG DLY
00m [00m] 5m
10m
15m
FACTORY DEFLTS
NO [NO]
YES
EXIT
NO [NO]
YES
2m@50%
3m@50%
* Unit specific
A/TUHMB060
3T [3T] 1.5T 2T 2.5T
A/TUHMB080
3T [3T] 3.5T 2T 2.5T
A/TUHMC100
4T [4T] 2.5T 3T 3.5T
A/TUHMD120
5T [5T] 3.5T 4T
A/TDHMB060
3T [3T] 1.5T 2T 2.5T
A/TDHMB080
3T [3T] 3.5T 2T 2.5T
A/TDHMC100
4T [4T] 2.5T 3T 3.5T
A/TDHMD120
5T [5T] 3.5T 4T
** Unit specific
A/TUHMB060
960 [960] 1080 830 900
A/TUHMB080
1400 [1400] 1610 1120 1260
A/TUHMC100
1620 [1620] 1790 1460 1540
A/TUHMD120
1890 [1890] 2000 1700 1790
A/TDHMB060
1040 [1040] 1160 900 950
A/TDHMB080
1400 [1400] 1610 1300 1350
A/TDHMC100
1650 [1650] 1700 1500 1600
A/TDHMD120
1850 [1850] 2040 1660 1760
18-CD30D1-9