Venting Materials - Trane UHMB060ACV3VA Installer's Manual

Upflow/ horizontal and downflow/ horizontal, gas-fired, direct vent, variable speed inducer, modulating condensing communicating furnaces
Hide thumbs Also See for UHMB060ACV3VA:
Table of Contents

Advertisement

Installer's Guide
PVC VENT FITTING MATERIAL These fittings are available from your Gas Furnace Distributors for U.S. applications
only.
ASTM STANDARD
F891
D2665
D1785
D2241
ASTM STANDARD
D2846
F441
F442
ASTM STANDARD
D2661
F628
*
- Allowable temperatures based on classifications covered in ASTM D4396 [Deflection Temps Under Load (264 PSI)]
** - Allowable temperatures based on classifications covered in ASTM D1784 [Deflection Temps Under Load (264 PSI)]
*** - Allowable temperatures based on classifications covered in ASTM D3965 [Deflection Temps Under Load (264 PSI)]
5. Wipe all excess cement from the joint with a rag.
Allow 15 minutes before handling. Cure time varies
according to fit, temperature and humidity.
NOTE:
Follow venting instructions carefully when using PVC ce-
ment.
IMPORTANT:
All joints must be water tight. Flue condensate is some-
what acidic, and leaks can cause equipment damage.
IMPORTANT:
Products installed in Canada must use vent systems
that are certified to the Standard for Type BH Gas
Venting Systems (ULC S636) for Class II-A venting
systems (up to 65 degrees C). Components of the vent
system must not be interchanged with other vent sys-
tems or unlisted pipe or fittings. Plastic components,
specified primers, and glues must be from a single
system manufacturer and not intermixed with other
system manufacturer's vent system parts.
18
KIT02282
PLASTIC PIPE DESIGNATIONS
PIPE TYPE
CELLULAR CORE
DWV PIPE
SCH 40, 80, 120
SDR SERIES
PIPE TYPE
CPVC 41
SCH 40, 80
SDR SERIES
PIPE TYPE
SCH 40 DWV
SCH 40 DWV CELLULAR CORE
TABLE 9
PVC
ALLOWABLE TEMPERATURE
*158
**158
**158
**158
CPVC
ALLOWABLE TEMPERATURE
**212
**212
**212
ABS
ALLOWABLE TEMPERATURE
***180
***180
g
VENT AND INLET AIR CONNECTIONS
Seal INLET AIR PIPE
with RTV sealant
Connection of the pipe and collar of the combustion air
inlet should just be a friction fit. It is recommended that
the inlet air joint be sealed with RTV type sealant to al-
low the joint to be separated for possible future service.
The inlet and vent pipes must be properly supported
throughout the entire length.
KIT02281
MARKING
ASTM F891
ASTM D2665
ASTM D1785
ASTM D2241
MARKING
ASTM D2846
ASTM F441
ASTM F442
MARKING
ASTM D2661
ASTM F628
Seal VENT PIPE
with RTV sealant
Front of Furnace
18-CD30D1-9