Advertisement

Installer's Guide
v
SUPPORT HORIZONTAL PIPE EVERY 3'
0" WITH THE FIRST SUPPORT AS CLOSE
TO THE FURNACE AS POSSIBLE.
INDUCED DRAFT BLOWER, HOUSING,
AND FURNACE MUST NOT SUPPORT
THE WEIGHT OF THE FLUE PIPE.
b
n
REMOVE RIBS
FROM CAP
COMBUSTION
AIR
ROOF BOOT
(FIELD SUPPLIED)
VENT
BAYAIR30AVENTA (VERTICAL)
For Canadian applications only, IPEX 196006 may be
used for vertical or horizontal vent terminations.
26
12 INCHES MIN. CLEARANCE MUST BE
MAINTAINED ABOVE HIGHEST
ANTICIPATED SNOW LEVEL.
MAXIMUM NOT TO EXCEED
24 INCHES ABOVE ROOF.
MAINTAIN 12 IN.
VENT
MINIMUM CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL. MAXIMUM OF
24 IN. ABOVE ROOF
SUPPORT
(FIELD SUPPLIED)
ELBOW
(FIELD SUPPLIED)
COMBUSTION
AIR
CONCENTRIC VENT
ROOF INSTALLATION
REMOVE RIBS
FROM CAP
MAINTAIN 12 IN.
MINIMUM CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL. MAXIMUM OF
24 IN. ABOVE ROOF.
For Canadian applications only,
IPEX 196006 may be used for
vertical or horizontal vent
ROOF TOP APPLICATION
terminations.
m
VENT
COMBUSTION
AIR
CONCENTRIC VENT
18-CD30D1-9