Configuration Manual
Ascom i75 VoWiFi Handset
2
Select "Enable" in the Unread message reminder drop-down list to activate the
reminder.
3
Enter reminder interval in the Message reminder interval text field.
8.6.5
Emergency Number
If the Alarm profile (Alarm > Emergency call) is set to "Enable" or "Enforce" and the
emergency number is called from the handset an alarm is automatically triggered.
1
Select Device > General.
2
Enter the emergency number in the Emergency number text field.
8.6.6
Alarm Settings
The following alarm types can be configured; Push-button alarm, Test alarm, Man-down
alarm, No-movement alarm and Emergency call.
1
Select Alarm > Common.
2
Enter text to be displayed as pop-up text when the alarm has been sent in the
Status text if alarm OK text field.
3
Enter text to be displayed as pop-up text if the alarm failed to be sent and is sent
again in the Status text if alarm is resending text field.
4
Enter text to be displayed as pop-up text if the alarm could not be sent in the Status
text if alarm failed text field.
Figure 14. Status text failure text field.
5
Enter data to be sent in the alarm block in the Alarm data text field.
Alarm Type
This section describes how to configure the alarm button. The procedure is similar for Test
alarm, No-movement alarm and Man-down alarm.
1
Select Alarm > Button.
2
Select one of the following in the alarm profile drop-down list:
• Disable - The alarm type is disabled.
• Enable - The alarm type is enabled but can be disabled by the user.
• Enforce - The alarm type is enabled and cannot be disabled by the user.
Figure 15. Enforced
3
Enter number to call in the Call number after the alarm text field.
4
Select "Enable" to activate ALS in the ALS drop-down list.
5
Enter alarm text in the alarm type text field.
6
Select connection method in the Call after the alarm connection method drop-
down list:
• Monitor - The loudspeaker is muted and the microphone is on.
• Loud - The loudspeaker is turned on.
• Ordinary - The loudspeaker is turned off
Emergency Call
To activate this alarm type the Emergency number (Device > General) must also be set.
1
Select Alarm > Emergency call.