Kelvinator Reverse Cycle User Manual

Kelvinator Reverse Cycle User Manual

Window/wall (electronic) - h type

Advertisement

20
2010
66129904148

Advertisement

Table of Contents
loading

Summary of Contents for Kelvinator Reverse Cycle

  • Page 1 2010 66129904148...
  • Page 2 CONTENTS 1. SAFETY PRECAUTIONS..............2. UNIT PARTS IDENTIFICATION............3. OPERATING INSTRUCTIONS ............4. INSTALLATION INSTRUCTIONS............. 5. TROUBLESHOOTING ..............ead This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 ! CAUTION Do not clean the air Ventilate the room well when When the air filter is to be removed, do not touch the conditioner with water. used together with a stove, metal parts of the unit. etc. It may cause an injury. Water may enter the unit and An oxygen shortage may occur.
  • Page 5 Safety Prior to Operation Precautions Preparing for operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5.
  • Page 6 ON OFF MODE CLOCK SWING TIMER ON TIMER OFF ENERGY LIGHT SAVER SLEEP...
  • Page 7: Operating Instructions

    OPERATING INSTRUCTIONS Controls The electronic control keypad will look like one of the following: Revers e Cycle Models ( 9,000BTU/h Models) Cooling Only Models ( 9,000BTU/h Models) Vent Control The vent control is located above the control knobs. (see the following figures). For maximum cooling efficiency, CLOSE the vent.
  • Page 8 beside There is no green indicator light for “Auto” mode. When you select “Auto” mode, a beep will sound indicating this “MODE” option was selected. within 0~10 hours and 1 hour increments within 10~24 hours. within 0~10 hours and 1 hour decrements within 10~24 hours.
  • Page 9 This mode is used to decrease the humidity in the room. The temperature setting are adjustable between 16 C to 30 C . Cooling begins automatically when the room temperature is 1 C above the set point, and stops when the room temperature is 1 C below the set point. The fan will not stop running. The temperature settings are adjustable between 16 C to 30 C in heating mode.
  • Page 10 MODE ON OFF CLOCK SWING TIMER ON TIMER OFF ENERGY LIGHT SAVER SLEEP LIGHT: Turn the unit LED light on or off only. ENERGY SAVER: Activate the “ENERGY SAVER” mode. CLOCK: Press this button to set clock.
  • Page 11 (23 ft) TIMER ON : Press the "TIMER ON" button to activate the auto start timer function. Auto start can be set from 1/2-24 hours. At unit off, press "TIMER ON" button,"HOUR ON" on the display will blink and during 5 seconds blinking, the value can be adjusted by pressing + or - button, every press of this button, 1/2 hour will be increased or decreased, but continuously press the + or - button, 2 seconds later, the value will be changed quickly, 1/2 hour will be increased in every 1/4 second automatically...
  • Page 12 ENERGY SAVER: Press “ENERGY SAVER” to activate or disactivate the ENERGY SAVER Function. In this mode, the fan will continue to run for 1 minute after compressor shuts off. LIGHT: Press this button at unit On, the light on the main unit will be turned on or off. Light On is defaulted when power on.
  • Page 15: Installation Instructions

    3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling and heating (reverse cycle models only) efficiency of the air conditioner.
  • Page 16 Installation of the Housing NOTE: UNIT MAY BE SUPPORTED BY A Step 1 SOLID FRAME FROM BELOW OR BY A HANGER FROM A SOLID Remove the air conditioner from it's packaging, remove fixing OVERHEAD SUPPORT. screws and slide the air conditioner out of it's housing (Refer FLASH OR SEAL AROUND EXTERNAL WALL FRAME OR ARCHITRAVE to Installation Steps).
  • Page 17 1. Hold the slot under the front panel, then uplift it outwards, and remove the front panel (See Fig.3). 2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside (See Fig.4). Fig.
  • Page 18: Normal Operation

    TROUBLESHOOTING Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Normal Operation You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve cooling efficiency.
  • Page 19 Warranty 7. Proof of purchase is required before you can make a claim under this warranty. 8. You may not make a claim under this warranty unless the FOR SALES IN USTRALIA AND EALAND defect claimed is due to faulty or defective parts or APPLIANCE : [E LECTROLUX...
  • Page 20 66129904148...

This manual is also suitable for:

Cooling only

Table of Contents