This mode is used to decrease the humidity in the room.
The temperature setting are adjustable between 16 C to 30 C . Cooling begins
automatically when the room temperature is 1 C above the set point, and stops
when the room temperature is 1 C below the set point. The fan will not stop running.
The temperature settings are adjustable between 16 C to 30 C in heating mode.
the fan speed is optional.
When heating stops, there may be a slight delay of 30 seconds for the fan
motor to stop.
For the cooling only models, after selecting "AUTO" by "MODE" keypad,the unit
will select the appropriate operating mode from FAN, COOL or DRY based upon the
temperature difference between the actual and desired room temperature.
For the cooling and heating models,after selecting "AUTO" by "MODE" keypad,the
unit will select the appropriate operating mode for Cool,Heat or Dry based upon the
temperature difference between the actual and desired room temperature.The default
heating temperature set point
Note: This Function can only be activated by remote control, Please refer to remote
operating instruction for more detail information
FILTER:
This feature is a reminder to clean the Air Filter (See Air Filter) for more efficient
operation.The light will illuminate after 250 hours of operation.To reset after cleaning
the filter, press the "FILTER" button and the light will go off.
DEFROST:
Under heating mode, when there is "H1" on the LED display indicates the unit is under
defrost function. In this case, any set on main unit or remote controller will not be
carried out until the defrost is completed.
FAILURE INDICATOR DISPLAY:
Indicates a malfunction of the indoor room temperature sensor
Indicates a malfunction of the evaporator temperature sensor
Indicates a malfunction of the outdoor condenser temperature sensor
When one of the above malfunctions occurs, turn off the unit, and check for
any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer or its service
agents or a similar qualified person for service.
O
O
o
is 20
C,the default cooling temperature set point is 25
8
O
O
O
O
o
C.