4.2.2
Status icons
Icon
Space operation mode = Heating.
Not available.
Unit is operating.
Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
▪ On  the  room  temperature  home  page:  Desired
room  temperature  =  according  to  the  selected
schedule.
▪ On  the  DHW  tank  temperature  home  page:
DHW tank mode = Scheduled mode.
DHW tank mode = Reheat mode.
DHW tank mode = Scheduled + reheat mode.
 
At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
The system will produce domestic hot water for the
indicated number of persons.
The DHW tank booster mode is active or ready to be
activated.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Child lock mode and/or function lock mode is active.
An external heat source is active. Example: Gas
burner.
The disinfection mode is active.
A malfunction occured. Press 
information about the malfunction.
Weather­dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
INFORMATION
Quiet mode is NOT applicable for this unit.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749­1 – 2013.06
Description
 to display more
4.3
Basic usage
4.3.1
Using home pages
About home pages
You  can  use  the  home  pages  to  read  out  and  change  settings  that
are  meant  for  daily  usage.  What  you  can  see  and  do  on  the  home
pages  is  described  where  applicable.  Depending  on  your  system
layout, the following home pages may be possible:
▪ Room temperature (Room)
▪ Main leaving water temperature (LWT main)
▪ Additional leaving water temperature (LWT add)
▪ DHW tank temperature (Tank)
To go to a home page
1 Press 
.
Result: One of the home pages is displayed.
2 Press 
 again to display the next home page (if any).
4.3.2
Using the menu structure
About the menu structure
You  can  use  the  menu  structure  to  read  out  and  configure  settings
that are NOT meant for daily usage. What you can see and do in the
menu  structure  is  described  where  applicable.  For  an  overview  of
the  menu  structure,  see 
"4.8  Menu  structure:  Overview"  on  page
18.
To go to the menu structure
1 From a home page, press 
Result: The menu structure is displayed.
Set time/date
Holiday
Quiet mode
Operation mode
Heating
Select schedules
Information
Select
Scroll
To navigate in the menu structure
Use 
 and 
.
4.3.3
Turning ON/OFF controls
About turning ON/OFF controls
Before you can control...
Room temperature
Main (+ additional) leaving water
temperature
DHW tank temperature
If you turn ON...
Room temperature control
Main (+ additional) leaving water
temperature control
4 Operation
.
1
>
>
Auto
>
>
You have to turn ON...
Room temperature control
(Room)
Main (+ additional) leaving water
temperature control (LWT main
and LWT add)
Main and additional leaving
water temperature control are
always turned ON or OFF
together.
Domestic hot water control
(Tank)
Then...
Main (+ additional) leaving water
temperature control is
automatically turned ON.
Room temperature control is
NOT automatically turned ON.
User reference guide