PROTECTION
Operating condition
The protective device maybe trip and stop the
appliance in the cases listed below.
Outdoor air temperature is over 24°C
HEATING
Outdoor air temperature is below -7°C
Room temperature is over 27°C
Outdoor air temperature is over *43°C
COOLING
Room temperature is below 21°C
DRY
Room temperature is below 18°C
* For Tropical (T3) Climate condition models, the
temperature point is 52°C instead of 43°C.
If the air conditioner runs in COOLING or DRY
mode with door or window opened for a long
time when relative humidity is above 80%, dew
may drip down from the outlet.
Noise pollution
• Install the air conditioner at a place that can bear
its weight in order to operate more quietly.
• Install the outdoor unit at a place where the air
discharged and the operation noise would not
annoy your neighbours.
• Do not place any obstacles in front of the air
outlet of the outdoor unit lest it increases the
noise level.
EMERGENCY OPERATION
Under emergency situation or when remote
control is missing, you can control the unit by
pressing the emergency button located on the
indoor unit.
• Turn on the appliance: when the unit is off, press
this button, it will start up.
• Turn off the appliance: when the unit is on, press
this button, the unit will stop working.
Features of protection device
1. Protection device
Wait at least 3 minutes before restarting the unit
after operation stops or changing mode during
operation.
After connecting to power supply and turning on
the appliance immediately, a delay of 20 seconds
may occur before it starts to operate.
2. If all operation has stopped, press ON/OFF
button again to restart. Timer should be set
again if it has been cancelled.
Features of HEATING mode
Preheating
2-5 minutes are necessary to preheat the indoor
unit at HEATING operation start.
Defrosting (out door unit)
In HEATING operation the appliance will defrost
(de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During
defrosting, fan stops operation.
After defrosting completes, it returns to
HEATING mode automatically.
Note: Heating is NOT available for cooling only
air conditioner models.