Specifications - Procom MN060HPA Owner's Operation And Installation Manual

Vent-free natural gas space heater, infrared models
Table of Contents

Advertisement

1. Model MN060HPA shall not be installed
in a bedroom. Models MN100HPA and
MN100TPA shall not be installed in a
bedroom or bathroom.
2. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See Air
Combustion and Ventilation
for
7 through 9. If heater keeps shutting off,
Troubleshooting
see
3. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
4. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
5. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
MODEL
Ignition
Gas Type
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Weight
Shipping Weight
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
4
, pages
, page 21.

SPECIFICATIONS

MN060HPA
Piezo
Natural Gas
6,000
6" W.C.
Maximum 10.5"
Minimum 7"
12 lbs
15 lbs
Heater Dimensions (HxWxD) 19
Carton Dimensions (HxWxD) 22" × 16
www.usaprocom.com
SAFETY
6. Always run heater with control knob at ON,
LOW or HIGH locked positions. Never set
control knob between locked positions.
Poor combustion and higher levels of
carbon monoxide may result.
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
8. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
9. Turn off heater and let cool before servic-
ing. Only a qualified service person should
service and repair heater.
10. Operating heater above elevations of
4,500 feet could cause pilot outage.
MN100HPA
Piezo
Natural Gas
5,500/10,000
6" W.C.
Maximum 10.5"
Minimum 7"
13 lbs
16 lbs
/
" × 14
1
8
MN100TPA
Piezo
Natural Gas
10,000
6" W.C.
Maximum 10.5"
Minimum 7"
14 lbs
17 lbs
/
" × 6
/
"
1
3
8
8
/
" × 8
/
"
3
1
4
8
200048-01A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN060HPA and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Mn100hpaMn100tpa

Table of Contents