Specifications; Product Features; Local Codes - Procom HearthSense BF30T-BB Owner's Operation And Installation Manual

Vent-free gas wall heater. blue flame models
Table of Contents

Advertisement

Available languages

Available languages

Note: Dimensions listed are outer most points on the
heater (includes control knobs and grill).
* For purposes of input adjustment.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
THERMOSTATIC CONTROL
The control automatically cycles the burner
on and off to maintain a desired room
temperature.
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free op-
eration. State and local codes in some areas
prohibit the use of vent-free heaters.
200549-05A

SPECIFICATIONS

Model
BTU/Hr Input Max. (available)
BTU/Hr Input Min. (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Dimensions (HxWxD)
Carton Dimensions (HxWxD) 26.18" x 28.15" x 9.84"
Heater Weight
Shipping Weight
Electrical Requirement for Blower Kit (included)
Voltage • 120 VAC, 60 Hz

PRODUCT FEATURES

LOCAL CODES

BF30T-BB
Ignition
Piezo Ignitor
Gas Type
Natural
30,000
15,000
4" W.C.
Max. 9.5"
Min. 5"
24.1" x 25.5 x 8.46"
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
natural gas by having your qualified installer
follow the instructions on page 13 and the
markings on the heater.
State of Massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.
HearthSense
Propane
30,000
24,000
9" W.C.
Max. 14"
Min. 11"
27.6 lbs
31.9 lbs
5