Specifications - Procom MG10HBF Owner's Operation And Installation Manual

Vent-free gas wall heater
Table of Contents

Advertisement

Available languages

Available languages

1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a
bathroom. Heaters with a maximum input
over 10,000 Btu/Hr shall not be installed
in a bedroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See Air
for Combustion and Ventilation, pages 7
through 9. If heater keeps shutting off, see
Troubleshooting, page 22.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
Note: Dimensions listed are outer most points on the heater
(includes control knobs and grill).
* For purposes of input adjustment.
4

SPECIFICATIONS

Model
BTU/Hr Input Max. (available)
BTU/Hr Input Min. (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Dimensions (HxWxD) 21.2" x 15.79" x 6.85"
Carton Dimensions (HxWxD) 22.83" x 17.95" x 8.23"
Heater Weight
Shipping Weight
www.usaprocom.com
SAFETY
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
8. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
9. Turn off and unplug heater and let cool
before servicing. Only a qualified service
person should service and repair heater.
10. Operating heater above elevations of
4,500 feet could cause pilot outage.
11. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lbs. capacity.
MG10HBF
Ignition
Piezo Ignitor
Gas Type
Natural
10,000
5,000
4" W.C.
Max. 9.5"
Min. 5"
14.2 lbs
16.5 lbs
Propane
10,000
8,000
9" W.C.
Max. 14"
Min. 11"
200310-01B