Specifications; Safety - Procom WZN18HLA Manual

Vent-free yellow flame gas log heater
Table of Contents

Advertisement

MODEL
Ignition
Gas Type
Input Rating
Manifold Pressure
Inlet Gas Pressure*
(inches of water)
MODEL
Ignition
Gas Type
Input Rating
Manifold Pressure
Inlet Gas Pressure*
(inches of water)
* For purposes of input adjustment.
Only a qualified installer, service
agent, or local gas supplier may
install and service this product.
WARNING: Keep the appli-
ance area clear and free from
combustible materials, gasoline,
and other flammable vapors and
liquids.
WARNING: This appliance
is equipped for use with natural
gas OR propane gas. Field con-
version is not permitted.
This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance
is not convertible for use with
other gases.
DANGER: Carbon monoxide
poisoning may lead to death!
200068-01A

SPECIFICATIONS

WZN18(HL,MV)A WZN24(HL,MV)A
Piezo Ignitor
Natural
32,000 BTU/Hr
3" W.C.
Max. 10.5" W.C.
Min. 5" W.C.
WZL18(HL,MV)A WZL24(HL,MV)A
Piezo Ignitor
Propane/LP
32,000 BTU/Hr
8" W.C.
Max. 14" W.C.
Min. 11" W.C.

SAFETY

www.usaprocom.com
Piezo Ignitor
Natural
34,000 BTU/Hr
3" W.C.
Max. 10.5" W.C.
Min. 5" W.C.
Piezo Ignitor
Propane/LP
34,000 BTU/Hr
8" W.C.
Max. 14" W.C.
Min. 11" W.C.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the flu,
with headaches, dizziness or nausea. If you
have these signs, the heater may not be work-
ing properly. Get fresh air at once! Have heater
serviced. Some people are more affected by
carbon monoxide than others. These include
pregnant women, people with heart or lung
disease or anemia, those under the influence
of alcohol and those at high altitudes.
Natural And Propane/LP Gas: Natural and
Propane/LP gas are odorless. An odor-making
agent is added to the gas. The odor helps you
detect a gas leak. However, the odor added to
the gas can fade. Gas may be present even
though no odor exists.
WARNING: Do not use a
blower insert, heat exchanger
insert or any accessory not ap-
proved for use with this log set.
WARNING: Do not allow fans
to blow directly into the heater.
Avoid any drafts that alter burner
flame pattern including ceiling
fans. Altered burner patterns
can cause sooting.
WZN30MVA
Piezo Ignitor
Natural
40,000 BTU/Hr
3" W.C.
Max. 10.5" W.C.
Min. 5" W.C.
WZL30MVA
Piezo Ignitor
Propane/LP
40,000 BTU/Hr
8" W.C.
Max. 14" W.C.
Min. 11" W.C.
3

Hide quick links:

Advertisement

Table of Contents
loading