Liebert PB Series User Manual
Liebert PB Series User Manual

Liebert PB Series User Manual

Powerbank online ups 3kva/6kva

Advertisement

Dear Customer,
Please accept our thanks for giving us the privilege to serve you by
choosing a Liebert make 'UPS'.
If this is your first Liebert UPS, we hope it is the beginning of a long
relationship which delivers value to your organisation. If you already
own and use a Liebert product, we are doubly honoured by your decision
of continuing this relationship.
It is our constant endeavor to partner you for the growth and success of
your business. This philosophy is reflected in our Mission statement
"To deliver value through Air & Power Quality solutions to achieve
customer delight". Please do give us feedback to help us realize our
Mission.
Emerson Network Power (India) Private Limited

Advertisement

Table of Contents
loading

Summary of Contents for Liebert PB Series

  • Page 1 This philosophy is reflected in our Mission statement “To deliver value through Air & Power Quality solutions to achieve customer delight”. Please do give us feedback to help us realize our Mission. Emerson Network Power (India) Private Limited...
  • Page 2 5828405 : (00 91 22) 5800829 5828358 Emerson Network Power (India) Private Limited pursues a policy of continual product development and reserves the right to change the equipment without notice. @ Copyright 2001 by Emerson Network Power Unauthorized reproduction prohibited...
  • Page 3 REGISTERED AND HEAD OFFICE EMERSON NETWORK POWER (INDIA) PRIVATE LIMITED Plot No. C-20, Road No. 19, Wagle Industrial Estate, Thane - 400 604, INDIA. Phone : (00 91 22) 5807000 5828405 : (00 91 22) 5800829 5828358 ZONAL OFFICES MUMBAI B 414-424, Bhaveshwar Arcade,(opp.
  • Page 4 BRANCH OFFICES JAMSHEDPUR BARODA Kashi Kunj, Road No. 2, Gr. Floor 39/2, Arunodaya Society, Contractor’s area, Bistupur; Alkapuri, BARODA-390 005 JAMSHEDPUR - 831 001 Tel : 0265-314296, 330383 Tel : 0657 - 437549 Fax : 0265-314296, 330383 Fax : 0657 - 437549 CHANDIGARH LUCKNOW SCO-198 / 199 / 200,...
  • Page 5 Powerbank Online UPS PB Series - 3kVA/6kVA User Manual EMERSON NETWORK POWER (INDIA) PRIVATE LIMITED...
  • Page 6: Table Of Contents

    INDEX SECTION DESCRIPTION PAGE NO. IMPORTANT SAFETY INSTRUCTIONS INTRODUCTION INSTALLATION CONTROL & INDICATION OPERATING INSTRUCTIONS DETAILED PROCEDURE STARTUP PROCEDURE / QUICK REFERENCE TESTING THE UPS OPERATION MAINTENANCE SPECIFICATION OF UPS...
  • Page 7: Important Safety Instructions

    1. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ---------- This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. All of the data contained in this manual is very important to the proper operation and long term reliability of the UPS.
  • Page 8: Instructions

    Do not install or operate your UPS near water. Do not locate your UPS on an unstable cart, stand or table. Move the UPS and its supporting cart, stand or table with care. Quick stops, excessive force and uneven surface may cause the UPS and its support to overturn.
  • Page 9: Introduction

    INTRODUCTION Purpose of your Uninterruptible Power System (UPS) This Uninterruptible Power System is designed to provide a continuous supply of usable 220 Volt AC as power to computer and other electronic equipments during irregularities or failures of commercial AC power. The UPS protects against AC power line irregularities such as blackouts, sags, spikes and electromagnetic and radio frequency interference.
  • Page 10: Design Concept

    Design Concept The figure below shows the block diagram of the UPS. BYPASS INPUT RECTIFIER INVERTER STATIC SW OUTPUT TO CRITICAL LOAD CHARGER # - This shorting link is removed when connected with separate bypass source. BATTERIES The input to the UPS is 230 V, single phase supply. This is converted into DC power by the rectifier circuit for the inverter.
  • Page 11: Installation

    INSTALLATION WARNING : IMPROPER INSTALLATION WILL NULLIFY WARRANTY Unpacking and Inspection When unpacking the UPS shipping carton you will find the following contents and enclosed in a waterproof bag. The UPS itself User Manual The spares part consists of the fuse for replacement when necessary. Remove the unit from its shipping carton and examine it for damage or moisture.
  • Page 12 IMPORTANT: Select right power wire according recommended wire selection table 1 (Page 14) and connection diagram as per Figures 1 & 2 (Page 10 & 11). DANGER : The unit should be supplied by grounded source. DO NOT operate the unit without ground source. CAUTION: High DC voltage present on the battery connector when battery circuit breaker is turned on.
  • Page 13 EXTERNAL CONNECTION APPANGMENT SHORTING LINKS INPUT BYP. OUTPUT BATTERY FIG 1 : COMMON BYPASS ARRANGEMENT INPUT BYP. OUTPUT BATTERY FIG 2 : SEPARATE BYPASS ARRANGEMENT...
  • Page 14: Control & Indication

    4. CONTROLS & INDICATIONS Fig. 3 (Page 13) illustrates the control, indications and terminals on the UPS, also explained in the following paragraphs :- AC IN This indicator illuminates when the incoming utility power is available. FAULT This indicator illuminates under following conditions :- D.C.
  • Page 15 FIG. - 3 POWER BANK UPS SERIES PS 3000 FHHGG FHHGG Liebert FHHGGGJHJHJKJKJIUHYGY FHHGG FHHGG FHHGGKJHJJ FRONT VIEW AGS JHJKJK AGS JHJKJK REAR VIEW...
  • Page 16 Table 1-Wire Selection Guide Note 1. Based on ambient temperature of 30°C(86°F) 2. Rated 0 to 2000 volts; 65° C and 75°C 3. Not more than three conductors in raceway or cable or earth (directly buried) ALLOWABLE CURRENT FOR INSULATED COPPER CONDUCTORS Temp Rating 65°C (104°F) 75°C(167°F)
  • Page 17: Operating Instructions

    5. OPERATING INSTRUCTIONS DETAILED PROCEDURE : Before proceeding with the operating instructions ensure that your UPS has been installed correctly. The UPS equipment is provided with easy to use power cable snap on connectors with 1/3 meter cable length. This is to facilitate quick and easy installation and uninstallation at any point of time.
  • Page 18: Storage Instructions

    The UPS audible alarm should sound intermittently when the UPS is operating from the battery source. Connect a normal load to the UPS. Turn on the power switch. Disconnect the input power. Again the audible alarm should sound intermittently. When the UPS is under the back-up mode, a battery capacity sensitive beeping indicates the battery power status.
  • Page 19: Startup Procedure / Quick Reference

    START UP PROCEDURE - QUICK REFERENCE STARTING THE UPS ON MAINS Ensure that the input voltage is 230V, 50Hz, single phase. All the wiring connections should be made as under :- SHORTING LINKS INPUT BYP. OUTPUT BATTERY Initially, connect only the input line, neutral and earth connection. Switch ON the input isolator on the rear panel, the breaker on the left side as seen from the back of the unit.
  • Page 20 STARTING THE UPS ON BATTERY (BLACK START) As per the above connection diagram, connect only the battery to the UPS (Ensure that the batteries are in fully charged condition showing DC voltage greater than 205 VDC for the entire bank). Switch-on the battery breaker on the rear panel and the front panel ;ON / OFF’...
  • Page 21: Testing The Ups

    TESTING THE UPS The battery charger board is designed to supply a maximum of 7.5 A charging current. Depending on the externally connected batteries, the appropriate setting should be done before connecting the batteries. The battery manufacturer recommends a charging current which is 10% of the AH capacity rating.
  • Page 22: Operation

    OPERATION Powering UP the UPS Be sure that the UPS is connected to an acceptable commercial AC power source. Please refer to the ‘Connecting the UPS to Commercial AC’ guidelines in the “INSTALLATION” section of this manual. To power up the UPS turn on the Circuit breaker and the battery breaker at the rear panel.
  • Page 23: Maintenance

    8. MAINTENANCE Maintenance Procedure The unit is designed for easy maintenance. Very little customer maintenance is required. The following will help to ensure trouble-free operation for several years :- Vacuum the dust from the ventilation intake. Wipe the cover with a damp cloth. Periodically cut the input AC power to test the condition of batteries CAUTION:...
  • Page 24 If everything appears normal, check for any loose connection of wires. Locate a fuse mounted on a busbar between the DC capacitors and the IGBTs. Check for the healthiness of this fuse. If it is faulty, replace the same and attempt to restart the UPS.
  • Page 25: Specification Of Ups

    Detailed Technical Specification of Powerbank UPS Parameter Unit of Specification of Measurement Powerbank (UOM) 3kVA 5kVA 6kVA Input Voltage Volts 220, 1 Phase Permissible input voltage variation ± 25% Input frequency Permissible input frequency variation ± 10% Power walk-in Seconds No.
  • Page 26 Parameter Unit of Specification of Measurement Powerbank (UOM) 3kVA 5kVA 6kVA Output voltage distortion at a) Linear load <=3% b) Non-linear load with 3 :1 <=5% Crest factor Accoustic noise <53 <56 <56 Operating temperature Degree C 0 to 40 Degree C Relative Humidity (RH) 0 to 95% RH (noncondensing)
  • Page 27 5828405 : (00 91 22) 5800829 5828358 Emerson Network Power (India) Private Limited pursues a policy of continual product development and reserves the right to change the equipment without notice. @ Copyright 2001 by Emerson Network Power Unauthorised reproduction prohibited...
  • Page 28 REGISTERED AND HEAD OFFICE EMERSON NETWORK POWER (INDIA) PRIVATE LIMITED Plot No. C-20, Road No. 19, Wagle Industrial Estate, Thane - 400 604, INDIA. Phone (00 91 22) 5807000 5828405 (00 91 22) 5800829 5828358 ZOLAN OFFICES MUMBAI B414,Bhaveshwar Arcade, Opp. Shreyas cinema), LBS Road, Ghatkopar(W), MUMBAI - 400 086 Tel.
  • Page 29 BRANCH OFFICES BARODA JAMSHEDPUR 39/2, Arunodaya Society, Kashi Kunj, Road No. 2, Gr. Floor Alkapuri, BARODA - 390 005 CONTRACTOR’S AREA, Bistupur, JAMSHEDPUR - 831 001 Tel. : 0265-314296, 330383 Fax : 0265-314296,330383 Tel. : 0657 - 437549 Fax : 0657 - 437549 CHANDIGARH SCO0198 / 199 / 200, LUCHNOW...