Specifications; General Description; Characteristics - Panasonic KX-TDA600BX Service Manual

Hybrid ip-pbx
Table of Contents

Advertisement

KX-TDA600BX

4 SPECIFICATIONS

4.1.

GENERAL DESCRIPTION

Control Bus
Communication Bus
Switching
Power Input
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk (per shelf)
Music on Hold (MOH)
Paging
Serial Interface Port
Extension Connection Cable
Dimension
Weight (when fully mounted) Basic Shelf
4.2.

CHARACTERISTICS

Terminal Equipment Loop Limit
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Trunk Loop Limit
Hookswitch Flash/Recall Timing Range
BRI Cards Internal ISDN Mode
Door Opener Current Limit
External Relay Current Limit
External Sensor Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal Impedance
Original bus (16 bit, 8 MHz,10 megabytes per second)
H.100 bus conformity (1024 time slot)
Distributed Switching
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A, 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A, 50 Hz/60 Hz
+36 V DC (+12 V DC x 3, recommended maximum current per shelf is 28 Ah or lower)
300 ms (without using backup battery)
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 Ω maximum
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non-condensing)
From 10 x 3-party conference call to 4 x 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (max 115.2 kbps)
USB
1
SLT
DPT
APT
PT-interface CS
DSS Consoles and Add-on Key Module
Basic Shelf
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Under 16 kg (35.2 lb)
• • • • PT: KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40 Ω
• • • • SLT: 600 Ω including set
• • • • Doorphone: 20 Ω
• • • • CS: 130 Ω; PT-interface CS: 65 Ω
15000 Ω maximum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600 Ω maximum
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
24 V DC/30 V AC, 1 A maximum
24 V DC/30 V AC, 1 A maximum
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The Hybrid IP-PBX detects input from the sensor when the signal is under
100 Ω
600 Ω
10000 Ω
1 pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
1-pair wire (D1, D2)
1-pair wire (D1, D2)
6