Panasonic KX-TDA600BX Service Manual page 74

Hybrid ip-pbx
Table of Contents

Advertisement

KX-TDA600BX
Pin No.
87
VDDQ8
88
VSSQ8
89
nCS3
90
nCS2
91
VDD4
92
VSS4
93
nRAS
94
nRD/nCASS/nFRAME
95
RD/nWR
96
nWE2/nCAS2/DQM2/n
ICIORD
97
nWE3/nCAS3/DQM3/n
ICIORD
98
nWE6/nCAS6/DQM6
99
VDDQ9
100
VSSQ9
101
nWE7/nCAS7/DQM7/n
REG
102
D23
103
D24
104
D22
105
RXD
106
nDREQ0
107
nDREQ1
108
D25
109
D21
110
D26
111
D20
112
D27
113
VDDQ10
114
VSSQ10
115
D19
116
D28
117
VDD5
118
VSS5
119
D18
120
D29
121
D17
122
D30
123
D16
124
D31
125
VDDQ11
126
VSSQ11
127
D55
128
D56
129
D54
130
D57
131
D53
132
D58
133
D52
134
D59
135
VDDQ12
136
VSSQ12
137
D51/P19
138
D60
139
D50/P18
140
D61
141
D49/P17
142
D62
143
VDD6
144
VSS6
145
D48/P16
146
D63
147
VDDQ13
148
VSSQ13
149
MD0/SCK
150
MD1/TXD2
Pin Name
I/O
Power supply for IO(3.3V)
Power supply for IO(GND)
O
Chip select signal 3 for SDRAM on EMEC Card (reserved)
O
Chip select signal 2 for SDRAM on board
Power supply for CORE(1.5V)
Power supply for CORE(GND)
O
RAS signal for SDRAM
O
Read signal (nRD/nCAS)
O
Read_write signal (RD/nWR)
O
D16-23 write enable/CAS2 for SDRAM/nWE2/DQM2
O
D24-31 write enable/CAS3 for SDRAM/nWE3/DQM3
O
D48-55 write enable NOT USE
Power supply for IO(3.3V)
Power supply for IO(GND)
O
D56-63 write enable NOT USE
IO
Data Bus [23]
IO
Data Bus [24]
IO
Data Bus [22]
IO
Serial RX data 1 for debug port
IO
DMA Request 0 from USB Controller
IO
DMA Request 1 from USB Controller
IO
Data Bus [25]
IO
Data Bus [21]
IO
Data Bus [26]
IO
Data Bus [20]
IO
Data Bus [27]
Power supply for IO(3.3V)
Power supply for IO(GND)
IO
Data Bus [19]
IO
Data Bus [28]
Power supply for CORE(1.5V)
Power supply for CORE(GND)
IO
Data Bus [18]
IO
Data Bus [29]
IO
Data Bus [17]
IO
Data Bus [30]
IO
Data Bus [16]
IO
Data Bus [31]
Power supply for IO(3.3V)
Power supply for IO(GND)
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
IO
Data Bus (Pull up) NOT USE
Power supply for IO(3.3V)
Power supply for IO(GND)
I
RESET (Reset switch input port)
IO
Data Bus (Pull up) NOT USE
I
nLOS ( Loss of sync signal input port)
IO
Data Bus (Pull up) NOT USE
I
nSLFANALM (Shelf fan alarm input port)
IO
Data Bus (Pull up) NOT USE
Power supply for CORE(1.5V)
Power supply for CORE(GND)
O
nRXD2sel
IO
Data Bus (Pull up) NOT USE
Power supply for IO(3.3V)
Power supply for IO(GND)
I
CPU Mode
I
CPU Mode Serial interface for RS232C Port
Description
74

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents