Hws600P - TDK-Lambada HWS?HWS User Manual

Ac-dc switching power supply
Table of Contents

Advertisement

HWS
600P
ITEMS/UNITS
Voltage Range
Frequency
Power Factor (100/200VAC)(Typ) (*2)
Efficiency (100VAC)(Typ)
Input
Efficiency (200VAC)(Typ)
Current (100/200VAC)(Typ)
Inrush Current (100/200VAC)(Typ) (*4)
Leakage Current
Nominal Voltage
Average Current
Maximum Peak Current (100VAC/200VAC) (*1)
Average Power
Maximum Peak Power (100VAC) (*1)
Maximum Peak Power (200VAC) (*1)
Output
Maximum Line Regulation
Maximum Load Regulation
Temperature Coefficient
Maximum Ripple & Noise (0≤Ta≤70 C) (*5) mVp-p
Maximum Ripple & Noise (-10≤Ta<0 C) (*5) mVp-p
Hold-up Time (Typ)
Voltage Adjustable Range
Over Current Protection (100VAC) (*8)
Over Current Protection (200VAC) (*8)
Over Voltage Protection
Remote Sensing
Function
Remote ON/OFF Control
Parallel Operation
Series Operation
Monitoring Signal
Line DIP
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Environ-
ment
Vibration
Shock (In package)
Cooling
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
PFHC
Stan-
dards
EMI
Immunity
Weight (Typ)
Mechan-
ical
Size (W H D)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
(*1) Operating time at peak output is less than 5sec, duty is less than 35%. For details, refer to peak output condition.
When the peak output more than 5 sec is continued, the output is shut down, manual reset (CNT reset or Re power on).
(*2) At 100/200VAC, Ta=25
and average output power.
(*3) For cases where conformance to various safety specs (UL, CSA, EN) are required,to be described as 100 - 240VAC(50/60Hz).
(*4) First inrush current. Not applicable for the inrush current to Noise Filter for less than 0.2ms.
(*5) Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. At average output power.
(*6) 85 - 265VAC , constant load.
(*7) No load-Average load, constant input voltage.
(*8) OCP circuit will shut the output down, manual reset (CNT reset or Re power on).
(*9) OVP circuit will shut the output down, manual reset (CNT reset or Re power on).
(*10) At 100/200VAC , nominal output voltage and average output current.
(*11) Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz), Ta=25 .
(*12) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of average output power or average output current, whichever is greater.
(*13) As for DENAN, designed to meet at 100VAC.
(*14) At Ta=25
and average output power.
HWS600P Specifications
MODEL

HWS600P-24

(*3)
V
Hz
(*2)
(*2)
(*2)
A
A
(*11) mA
Less than 0.75 (0.2(Typ) at 100VAC / 0.44(Typ) at 230VAC)
VDC
24
A
25
A
40.5/83
W
600
W
W
1992
(*6) mV
96
(*7) mV
144
150
200
(*10) ms
VDC
19.2 - 26.4
A
>41.3
A
>84.6
(*9) VDC
27.6 - 32.4
(*12)
RH
RH
At no operating, 10 - 55Hz (Sweep for 1min) 19.6m/s² Constant, X,Y,Z 1hour each
Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG: 500VAC (100mA), Output-CNT: 100VAC(100mA) for 1min
More than 10M
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
(*13)
(*14)
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3), -5(Level 3,4), -6(Level 3), -8(Level 4), -11
g
mm
HWS600P-36
85 - 265VAC or 120 - 330VDC
47 - 63
0.99/0.94
84
87
7.2/3.7
20 / 40
36
16.7
27/55.5
601.2
972
1998
144
216
Less than 0.02% / C
200
250
20ms
28.8 - 39.6
>27.5
>56.6
41.4 - 48.6
-
Possible
Possible (2 units Max)
Possible
PF(Open Collector Output)
Designed to meet SEMI-F47 (200VAC Line only)
-10 - +70 (-10 - +50:100%,+70:50%)
-30 - +85
10 - 90 (No dewdrop)
10 - 95 (No dewdrop)
Less than 196.1m/s²
Forced Air By Blower Fan
More than 100M
Output - FG : 500VDC
Output -CNT : 100VDC at 25 C and 70%RH
Designed to meet DENAN
Designed to meet IEC61000-3-2
1600
100 x 82 x 165 ( Refer to Outline Drawing )
HWS600P-48
48
12.5
20/41.5
600
960
1992
192
288
350
400
38.4 - 52.8
>20.4
>42.3
55.2 - 64.8