Hws1000/Me - TDK-Lambada HWS?HWS User Manual

Ac-dc switching power supply
Table of Contents

Advertisement

HWS
1000/ME
HWS1000/ME Specifications
ITEMS/UNITS
Voltage Range
Frequency
Power Factor (100/200VAC)(typ) (*1)
Input
Efficiency (100/200VAC)(typ)
Current (100/200VAC)(typ)
Inrush Current (100/200VAC)(typ) (*3)
Leakage Current
Nominal Voltage
Maximum Current
Maximum Peak Current
Maximum Power
Maximum Peak Power
Maximum Line Regulation
Output
Maximum Load Regulation
Temperature Coefficient
0 to +71
Maximum
Ripple & Noise
(*4)
Hold-up Time (typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Remote ON/OFF Control
Function
Parallel Operation
Series Operation
Monitoring Signal
Line DIP
Operating Temperature
-10 to +40°C
Storage Temperature
Environment
Operating Humidity
Storage Humidity
Vibration
Shock (In package)
Cooling
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
PFHC
Voltage Fluctuations/Flicker Emissions
Standards
EMI
Immunity
Weight (max)
Mechanical
Size (W H D)
(*1) At Ta=25
and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required,input voltage range will be 100 - 240VAC(50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. (at 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
(*5) 85 - 265VAC , constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the
output to shutdown.
Output current exceeding maximum rated output current for more than 10 seconds continuously
will result to output shutdown.
(*8) OVP circuit will shut down output, manual reset (Power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 .
When using it as a patient care equipment, all outer surfaces of the equipment
shall be constructed of nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90(C-UL) basic insulation.
(*13) Peak output current is less than 10 seconds, and duty 35% max. (200VAC Line only)
(Read instruction manual carefully, before using the power supply unit.)
MODEL
(*2)
V
(*2) Hz
(*1)
85/87
(*1)
A
A
(*10) mA
VDC
24
A
46
(*13)
A
58.5
W
(*13)
W
(*5) mV
96
(*6) mV
mVp-p
150
-10 to 0
mVp-p
180
(*9) ms
VDC
19.2-28.8
(*7)
A
>61.4
(*8) VDC
30.0-34.8
(*11)
+50°C
+71°C
RH
RH
Output-FG : 500VAC (300mA), Output-CNT:100VAC (100mA) for 1min.
More than 10M
(*12)
Approved by UL60601-1, EN60601-1,CSA C22.2 No.601.1-M90(C-UL)
Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-ClassA, CISPR-ClassA.
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
g
mm
AC85 - 265 or DC120 - 330
47 - 63
0.98/0.95
85/88
13.5/7.0
20/40
Less than 0.5 (0.2(Typ) at 100VAC / 0.4(typ) at 230VAC)
36
30.7
39
1104
1404
144
150
Less than 0.02%/
240
20
28.8-43.2
>40.9
45.0-49.7
Possible
Possible
Possible
Possible
PF(Open collector output)
Built to meet SEMI-F47 (200VAC Line only)
-10 to + 71, Start up -20 to +71
100
100
50
-30 to +85
10 - 90 ( No Condensing )
10 - 95 ( No Condensing )
At no operating, 10 - 55Hz (Sweep for 1min.)
19.6m/s² Constant, X,Y,Z 1hour each.
Less than 196.1m/s²
Forced Air By Blower Fan
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
More than 100M
Output - FG : 500VDC
Output - CNT : 100VDC at 25
Built to meet IEC61000-3-2
Built to meet IEC61000-3-3
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
3200
126.5 x 82 x 240 ( Refer to Outline Drawing )
86/88
48
23
29.2
192
300
200
500
38.4-52.8
>30.6
55.2-60.0
and 70%RH