Hws100 - TDK-Lambada HWS?HWS User Manual

Ac-dc switching power supply
Table of Contents

Advertisement

HWS
100
HWS100 Specifications
ITEMS/UNITS
Voltage Range
Frequency
Power Factor (100/200VAC)(typ) (*1)
Input
Efficiency (100/200VAC)(typ)
Current (100/200VAC)(typ)
Inrush Current (100/200VAC)(typ) (*3)
Leakage Current
Nominal Voltage
Maximum Current
Maximum Power
Maximum Line Regulation
Maximum Load Regulation
Output
Temperature Coefficient
Maximum Ripple & Noise (0≤Ta≤70 )(*4) mVp-p
Maximum Ripple & Noise ( 10≤Ta< 0 ) (*4) mVp-p
Hold-up Time (typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Function
Remote ON/OFF Control
Parallel Operation
Series Operation
Line DIP
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Environment
Vibration
Shock (In package)
Cooling
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
PFHC
Standards
EMI
Immunity
Weight (typ)
Mechanical
Size (W x H x D)
(*1) At 100/200VAC, Ta=25
and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC (50/60Hz).
(*3) Not applicable for the in-rush current to noise filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit and hiccup with automatic recovery.
Not operate at over load or dead short condition for more than 30 seconds.
(*8) OVP circuit will shutdown output, manual reset (re power on).
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz).
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve
(*12) As for DENAN, built to meet at 100VAC.
(Read instruction manual carefully, before using the power supply unit.)
MODEL

HWS100-3

HWS100-5
(*2)
V
(*2) Hz
0.98 / 0.90
(*1)
78 / 81
(*1)
A
0.9 / 0.45
A
(*10) mA
Less than 0.5. (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)
VDC
3.3
A
20
W
66
100
(*5) mV
20
(*6) mV
40
120
160
(*9) ms
VDC
2.97 - 3.96
4.0 - 6.0
(*7)
A
>21.0
(*8) VDC
4.13 - 4.95
6.25 - 7.25
(*11)
RH
RH
At no operating, 10 - 55Hz (sweep for 1min) 19.6m/s² constant,
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
More than 100M
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1, EN50178 UL508 (with cover models only),
(*12)
CSA C22.2 No.14-M95 (with cover models only) Built to meet, DENAN
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
g
mm
HWS100-12
HWS100-15
AC85 - 265 or DC120 - 370
47 - 63
0.99 / 0.95
83 / 86
1.3 / 0.65
14 / 28, Ta=25 , cold start
5
12
15
8.5
7
102
105
48
60
96
120
Less than 0.02% /
150
180
20
9.6 - 14.4
12.0 - 18.0
>8.92
>7.35
15.0 - 17.4
18.8 - 21.8
Possible
Possible (/R Option)
-
Possible
Built to meet SEMI-F47 (200VAC Line only)
-10 to +70 (-10 to +50: 100%, +60: 60%, +70: 20%)
-30 to +85
30 - 90 (No dewdrop)
10 - 95 (No dewdrop)
X, Y, Z 1hour each.
Less than 196.1m/s²
Convection cooling
Output - FG : 500VAC (100mA) for 1min
at 25
and 70%RH Output - FG : 500VDC
Built to meet IEC61000-3-2
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
450
28 x 82 x 160 (Refer to outline drawing)
HWS100-24
HWS100-48
84 / 87
24
48
4.5
2.1
108
100.8
96
192
192
384
200
240
19.2 - 28.8
38.4 - 52.8
>4.72
>2.20
30.0 - 34.8
55.2 - 64.8