Hws30/Me - TDK-Lambada HWS?HWS User Manual

Ac-dc switching power supply
Table of Contents

Advertisement

HWS
30/ME
HWS30/ME Specifications
ITEMS/UNITS
Voltage Range
Frequency
Efficiency (100/200VAC)(typ)
Input
Current (100/200VAC)(typ)
Inrush Current (100/200VAC)(typ) (*3)
Leakage Current
Nominal Voltage
Maximum Current
Maximum Power
Maximum Line Regulation
Maximum Load Regulation
Output
Temperature Coefficient
Maximum Ripple & Noise (0≤Ta≤70 ) (*4) mVp-p
Maximum Ripple & Noise ( 10≤Ta
Hold-up Time (typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Function
Parallel Operation
Series Operation
Line DIP
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Environment
Vibration
Shock (In package)
Cooling
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
PFHC
Voltage Fluctuations / Flicker Emissions
Standards
EMI
Immunity
Weight (typ)
Mechanical
Size (W x H x D)
(*1) At 100/200VAC, Ta=25
and maximum output power.
(*2) For cases where conformance to various safety specs (UL, EN, CSA) are required, to be described as 100 - 230VAC (50/60Hz).
(*3) Not applicable for the in-rush current to noise filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
For start up at low ambient temperature and low input voltage, output ripple noise might not meet specification.
However, there is no overshoot at start up and output ripple noise specification can be met after one second.
(*5) 85 - 265VAC, constant load.
(*6) No load-full load, constant input voltage.
(*7) Foldback current limit with automatic recovery. Not operate at over load or dead short condition for more than
30 seconds.
(*8) OVP circuit will shutdown output, manual reset (re power on).
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, EN and CSA (at 60Hz). When using it as a patient care equipment,
all outer surfaces of the equipment shall be constructed of nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90, basic insulation.
(Read instruction manual carefully, before using the power supply unit.)
MODEL
HWS30-5/ME
(*2)
V
(*2) Hz
(*1)
77 / 80
(*1)
A
A
(*10) mA
VDC
5
A
6
W
(*5) mV
20
(*6) mV
40
120
0 ) (*4) mVp-p
160
(*9) ms
VDC
4.0 - 6.0
(*7)
A
>6.3
(*8) VDC
6.25 - 7.25
(*11)
RH
RH
More than 100M
(*12)
Approved by UL60601-1, EN60601-1, CSA-C22.2 No.601.1-M90
Designed to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3),
g
mm
HWS30-12/ME
HWS30-15/ME
AC85 - 265 or DC120 - 370
47 - 63
81 / 83
0.8 / 0.4
14 / 28 at Ta=25 , cold start
Less than 0.5. (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)
12
15
2.5
2
30
48
60
96
120
Less than 0.02% /
150
180
20
9.6 - 14.4
12.0 - 18.0
>2.62
>2.1
15.0 - 17.4
18.8 - 21.8
-
-
Possible
Designed to meet SEMI-F47 (200VAC Line only)
-10 to +70 (-10 to +50: 100%, +60: 60%, +70: 20%)
-30 to +85
30 - 90 (No dewdrop)
10 - 95 (No dewdrop)
At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² constant, X, Y, Z 1hour each.
Less than 196.1m/s²
Convection cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
at 25
and 70%RH Output - FG : 500VDC
Designed to meet IEC61000-3-2
Designed to meet IEC61000-3-3
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
220
26.5 x 82 x 95 (Refer to outline drawing)
HWS30-24/ME
HWS30-48/ME
83 / 86
82 / 83
24
48
1.3
0.65
31.2
96
192
192
384
200
240
19.2 - 28.8
38.4 - 52.8
>1.36
>0.68
30.0 - 34.8
55.2 - 64.8