Hws300/Me - TDK-Lambada HWS?HWS User Manual

Ac-dc switching power supply
Table of Contents

Advertisement

HWS
300/ME
HWS300/ME Specifications
ITEMS/UNITS
Voltage Range
Frequency
Power Factor (100/200VAC)(typ) (*2)
Input
Efficiency (100/200VAC)(typ)
Current (100/200VAC)(typ)
Inrush Current (100/200VAC)(typ) (*4)
Leakage Current
Nominal Voltage
Maximum Current
Maximum Power
Maximum Line Regulation
Maximum Load Regulation
Output
Temperature Coefficient
Maximum Ripple & Noise (0<Ta<70 ) (*5) mVp-p
Maximum Ripple & Noise ( 10<Ta< 0 ) (*5) mVp-p
Hold-up Time (typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Remote ON/OFF Control
Function
Parallel Operation
Series Operation
Monitoring Signal
Line DIP
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Environment
Vibration
Shock (In package)
Cooling
Withstand Voltage
Isolation
Isolation Resistance
Safety Standards
PFHC
Voltage Fluctuations / Flicker Emissions
Standards
EMI
Immunity
Weight (typ)
Mechanical
Size (W x H x D)
(*1) ( ):Peak output current at 200VAC. Operating time at peak output is less than 10 sec, duty is less than 35%.
(*2) At 100/200VAC, Ta=25
and maximum output power.
(*3) For cases where conformance to various safety specs (UL, EN, CSA) are required, to be described as 100 - 240VAC (50/60Hz).
(*4) Not applicable for the inrush current to noise filter for less than 0.2ms.
(*5) Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.
(*6) 85 - 265VAC, constant load.
(*7) No load-full load, constant input voltage.
(*8) Constant current limit with automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30 seconds.
(*9) OVP circuit will shut the output down, manual reset (CNT reset or re power on).
(*10) At 100/200VAC, nominal output voltage and maximum output current.
(*11) Measured by the each measuring method of UL, EN, and CSA (at 60Hz), Ta=25 .
When using it as a patient care equipment, all outer surfaces of the equipment shall be constructed of
nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*12) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*13) As for UL60601-1, EN60601-1 and CSA-C22.2No601.1-M90, basic insulation.
(Read instruction manual carefully, before using the power supply unit.)
MODEL
HWS300-12/ME
(*3)
V
(*3) Hz
(*2)
80 / 83
(*2)
A
A
(*11) mA
Less than 0.5. (0.15 (typ) at 100VAC / 0.39 (typ) at 230VAC)
VDC
12
(*1)
A
27
W
324
(*6) mV
48
(*7) mV
72
(*10) ms
VDC
9.6 - 14.4
(*8)
A
>28.4
(*9) VDC
15.0 - 17.4
(*12)
RH
RH
Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG: 500VAC (100mA), Output-CNT: 100VAC(100mA) for 1min
More than 10M
(*13)
Approved by UL60601-1, EN60601-1, CSA-C22.2 No601.1-M90
Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Designed to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3),
g
mm
HWS300-15/ME
HWS300-24/ME
AC85 - 265 or DC120 - 330
47 - 63
0.99 / 0.95
4.1 / 2.1
20 / 40
15
24
22
14 (16.5)
330
60
96
90
144
Less than 0.02% /
150
200
20
12.0 - 18.0
19.2 - 28.8
>23.1
>16.7
18.8 - 21.8
30.0 - 34.8
Possible
Possible
Possible
Possible
PF (Open collector output)
Designed to meet SEMI-F47 (200VAC Line only)
-10 to +70 (-10 to +50: 100%, +70: 50%)
-30 to +85
10 to 90 (No dewdrop)
10 to 95 (No dewdrop)
At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² constant, X, Y, Z 1hour each.
Less than 196.1m/s²
Forced air by blower fan
More than 100M
Output - FG : 500VDC
Output -CNT : 100VDC at 25
Designed to meet IEC61000-3-2
Designed to meet IEC61000-3-3
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
1000
61 x 82 x 165 (Refer to outline drawing)
HWS300-48/ME
82 / 85
48
7
336
192
288
350
400
38.4 - 52.8
>7.4
55.2 - 64.8
and 70%RH