DeVilbiss 306DS Instruction Manual

Portable oxygen system
Hide thumbs Also See for 306DS:

Advertisement

Model 306DS Instruction Guide
DeVilbiss® iGo™ Portable Oxygen System
EN
WARNING–Read instruction guide before operating this equipment.
CAUTION– Federal (U.S.A.) law restricts this device to sale by or on the order of a
physician.
DANGER–NO SMOKING
Sistema de oxígeno portátil iGo™ de DeVilbiss®
ES
ADVERTENCIA– Lea la guía de instrucciones antes de poner a funcionar este
equipo.
PRECAUCIÓN– La ley federal de EE. UU. limita la venta de este dispositivo a médicos
o a personas que dispongan de la correspondiente orden médica.
PELIGRO–NO FUMAR
Système d'approvisionnement portable en
FR
oxygène DeVilbiss® iGo™
AVERTISSEMENT– Lisez ce guide d'instructions avant d'utiliser l'équipement.
ATTENTION– En vertu de la loi fédérale américaine, cet appareil ne peut être vendu
que par un médecin ou sur ordonnance de celui-ci.
DANGER–NE PAS FUMER
Tragbares DeVilbiss® iGo™-Sauerstoffsystem
DE
WARNUNG– Vor Inbetriebnahme des Gerätes Bedienungshinweise lesen.
ACHTUNG– Nach US-Bundesgesetzen darf dieses Gerät nur von einem Arzt bzw. auf
Anordnung eines Arztes verkauft werden.
GEFAHR–RAUCHEN VERBOTEN
Sistema portatile DeVilbiss® iGo™ per
IT
ossigenoterapia™
AVVERTENzA– Non mettere in funzione l'apparecchiatura senza aver prima
letto le istruzioni riportate in questo manuale.
ATTENzIONE– La legge federale statunitense limita la vendita di questo dispositivo ai
medici o su loro prescrizione.
PERICOLO – VIETATO FUMARE
DeVilbiss® iGo™ draagbaar zuurstofsysteem
NL
WAARSCHUWING– Lees dit instructiehandboekje zorgvuldig door voordat u
het apparaat gaat gebruiken.
ATTENTIE– De federale wetgeving in de Verenigde Staten schrijft voor dat dit apparaat
uitsluitend mag worden verkocht of voorgeschreven door een arts.
GEVAAR– VERBODEN TE ROKEN
DeVilbiss® iGo™ bärbart syrgasystem
SV
VARNING - Läs användarhandledningen innan du använder denna utrustning.
VAR FÖRSIKTIG! Enligt federal lag (U.S.A.) får denna anordning endast säljas av
läkare eller på läkarordination.
FARA–RÖKNING FÖRBJUDEN
DeVilbissin® kannettava iGo™-happijärjestelmä
FI
VAROITUS - Lue käyttöopas ennen tämän laitteiston käyttöä.
HUOMIO - Yhdysvaltain liittovaltion lain mukaan tämän laitteen saa myydä
ainoastaan lääkäri tai lääkärin määräyksestä.
VAARA - EI SAA TUPAKOIDA
DeVilbiss® iGo™ bærbart oxygensystem
DA
ADVARSEL: Læs betjeningsvejledningen, før du betjener dette udstyr.
FORSIGTIG: I henhold til amerikansk lov må denne anordning udelukkende sælges af
eller på opfordring af en læge.
FARE – RYGNING FORBUDT
DeVilbiss® iGo™ bærbare oksygensystem
NO
ADVARSEL- Les instruksjonsveiledningen før du bruker dette utstyret.
FORSIKTIG - Føderal (USA) lovgivning begrenser denne anordningen til salg av eller
som foreskrevet av en lege.
FARE- INGEN RØYKING
Sistema de Oxigênio Portátil iGo™ DeVilbiss®
PT
CUIDADO – Leia o manual de instruções antes de operar o equipamento.
ATENÇÃO – A lei federal (EUA) restringe a venda deste aparelho a médicos ou
mediante prescrição médica.
PERIGO – PROIBIDO FUMAR
Φορητό σύστημα οξυγόνου DeVilbiss® iGo™
EL
ΠΡΟΕΙΔΟΠΟΙΗΣΗ– Διαβάστε το έγγραφο οδηγιών προτού θέσετε το μηχάνημα
σε λειτουργία.
ΠΡΟΣΟΧΗ– Το Ομοσπονδιακό δίκαιο(των Η.Π.Α.) περιορίζει την πώληση αυτής της
συσκευής μόνο σε ιατρό ή κατόπιν εντολής ιατρού.
ΚΙΝΔΥΝΟΣ–ΜΗΝ ΚΑΠΝΙΖΕΤΕ
DeVilbiss® iGo™ 便携式供氧系统
ZH
警告:请在操作本设备之前仔细阅读操作指南。
小心:美国联邦法律规定本设备只限医师购买或订购。
危险:禁止吸烟
0044

Advertisement

Table of Contents
loading

Summary of Contents for DeVilbiss 306DS

  • Page 1 DANGER–NO SMOKING FARA–RÖKNING FÖRBJUDEN Sistema de oxígeno portátil iGo™ de DeVilbiss® DeVilbissin® kannettava iGo™-happijärjestelmä ADVERTENCIA– Lea la guía de instrucciones antes de poner a funcionar este VAROITUS - Lue käyttöopas ennen tämän laitteiston käyttöä. equipo.
  • Page 2: Table Of Contents

    Provider Checklist ........................................IEC Symbols and Symbol Definitions ..................................Introduction ..........................................Indications for Use ........................................Important Parts of Your DeVilbiss iGo Personal Oxygen System iGo Portable Oxygen System and Accessories ..............................iGo Control Panel ......................................Accessories List ......................................... Setting Up Your iGo Portable Oxygen System ................................
  • Page 3: Important Safeguards

    Never use aerosol sprays or flammable anesthetics near the equipment� • Electric Shock Hazard� Do not disassemble� The DeVilbiss iGo Portable Oxygen System contains no user serviceable parts� If service is required, contact your DeVilbiss provider or authorized service center�...
  • Page 4: Physician Notes

    At The Office Upon arrival, check the iGo for damage that may have occurred during shipping and notify DeVilbiss of any damage. (Obvious shipping damage should be reported within 10 calendar days after arrival.) Do not use damaged equipment. Save the carton, noting the position of the unit and placement of the packing material for possible future return.
  • Page 5: Iec Symbols And Symbol Definitions

    InTRoDUCTIon This instruction guide will acquaint you with the DeVilbiss iGo Portable Oxygen System. Make sure that you read and understand this guide before operating your unit. Important safeguards are indicated throughout this guide; pay special attention to all safety information. Contact your DeVilbiss equipment provider should you have any questions.
  • Page 6: Igo Portable Oxygen System And Accessories

    4c. Red Service Required Light = Abnormal Operation/Malfunction, Concentration Below an Acceptable Oxygen Level; illuminates with an audible alert when there is a problem with your unit. Switch to your reserve oxygen system. Refer to Troubleshooting and/or call your DeVilbiss provider for instructions. Do not attempt any other maintenance. Mode Select Button and Flow Indicator Light 5a.
  • Page 7: Accessories List

    Certain oxygen accessories not specified for use with the iGo Portable Oxygen System may impair the performance� ONLY use recommended oxygen delivery accessories� Humidifier Kit includes Remote Stand, Humidifier, and Elbow Adapter (only for use in Continuous Flow mode) ........306DS-627 Humidifier (200 ml Capacity) - 50/case (only for use in Continuous Flow mode) ....................HUM16 Elbow Humidifier Adapter Kit ....................................444-507...
  • Page 8: Before Operating Your Igo

    Connect the AC Power Cord to the AC Adapter and to a grounded power outlet. Do not connect the iGo to an extension cord or to an electrical outlet controlled by a wall switch. No other appliances should be plugged into the wall outlet. NOTE– Use with grounded, 3-pin receptacle. DO NOT remove ground pin from cord. Use only with DeVilbiss approved cords. NOTE– The AC Power Cord used with the iGo must meet the requirements of the country where the product is used.
  • Page 9: Battery Operation

    Exposing the Battery to water or other liquids may cause personal injury� Replace the Battery with only approved DeVilbiss Rechargeable Battery� The iGo system can only work with a DeVilbiss Battery� Use of a damaged battery or a non-approved Battery may damage the unit, present a risk of fire or explosion, cause personal injury, and will void the warranty�...
  • Page 10: Initial Battery Operation

    Status Gauge Lights will also be lit indicating battery charge level. NOTE– The DeVilbiss iGo has an oxygen sensing device (OSD) to monitor oxygen purity once the oxygen stabilization process is complete (after approximately the first 20 minutes of operation). Once stabilized, the OSD monitors the oxygen purity and will alert if purity falls below an acceptable level.
  • Page 11: Travel

    ReseRve oXYGen sYsTeM As a precaution, your DeVilbiss provider may supply you with a reserve oxygen system. If your unit loses electrical power or fails to operate correctly, the Patient Alert System will sound to signal you to switch to your reserve oxygen system (if provided). Contact your DeVilbiss provider.
  • Page 12: Reserve Oxygen System

    The following troubleshooting chart will help you analyze and correct minor iGo malfunctions. If the suggested procedures do not help, switch to your reserve oxygen system and call your DeVilbiss homecare provider. Do not attempt any other maintenance. � WArning To avoid electric shock hazard, do not remove the covers�...
  • Page 13: Caring For Your Igo System

    Disconnect cords from the iGo before cleaning. Clean the cords by using a damp cloth with a mild household cleaner and wipe dry. Cannula and Tubing Clean and replace the cannula and tubing as instructed by your DeVilbiss provider. A-306...
  • Page 14: Specifications

    Exterior Covers and DeVilbiss Rechargeable Battery � WArning To avoid electric shock, do not remove the iGo covers� The covers should only be removed by a qualified DeVilbiss provider� Do not apply liquid directly to the covers or utilize any petroleum-based solvents or cleaning agents�...
  • Page 15: Declaration Of Conformity

    75-85% - Low O2 Light (yellow) < 75% - Service Required Light (red) and Audible Alert Electrical Power: DeVilbiss Rechargeable Battery (Lithium Ion) ............................8.8 Amp Hrs AC Adapter Input Voltage Range ..............................90-264 50/60 Hz DC Adapter ................................. 12 Volt Negative Ground Vehicles Adapter Manufacturer Info: AC Adapter ..................
  • Page 16 800-338- 198 8 • 81 4-44 3 - 4 8 8 1 • ww w. D e Vi l bi s sH e a l t h c a re . c o m ©2008 DeVilbiss Healthcare 11.08 A-306 Rev.