3x400V
3x400V
Output data at nom flow
0/35
Rated output
Cooling output
Electrical output
COP
0/50
Rated output
Cooling output
Electrical output
COP
Output data according to EN 14511:2011
0/35
Rated output
Electrical output
COP
EN14511
0/45
Rated output
Electrical output
COP
EN14511
Additional power
Electrical data
Rated voltage
Max operating current, compressor
Including Control system, Circulation pumps and 0 kW immer-
sion heater
(Recommended fuse rating)
Starting current
Max permitted impedance at connection point
Max operating current heat pump incl. 1 – 2 kW immersion
heater
(Recommended fuse rating)
Max operating current heat pump incl. 3 – 4 kW immersion
heater
(Recommended fuse rating)
Max operating current heat pump incl. 5 – 6 kW immersion
heater
(Recommended fuse rating)
Max operating current heat pump including 7 kW immersion
heater, connected upon delivery
(Recommended fuse rating)
Max operating current heat pump including 9 kW immersion
heater, requires switching
(Recommended fuse rating)
Output, Brine pump
Output, Heating medium pump
IP class
Refrigerant circuit
NIBE™ F1245
Refers to performance of heat pump excl. circulation pumps
1)
5
6
kW
4.89
6.48
kW
3.83
5.17
kW
1.06
1.31
-
4.62
4.94
kW
3.79
5.15
kW
2.61
3.61
kW
1.18
1.53
-
3.20
3.36
kW
4.65
6.07
kW
1.08
1.32
-
4.30
4.59
kW
3.98
5.19
kW
1.17
1.46
-
3.40
3.56
kW
1/2/3/4/5/6/7 (switchable to 2/4/6/9)
400V 3NAC 50 Hz
A
9.5(1-phase)
4.6(16)
rms
(16)
A
23
18
rms
ohm
-
-
A
18(20)
13(16)
rms
A
18(20)
13(16)
rms
A
18(20)
13(16)
rms
A
18(20)
19(20)
rms
A
24(25)
19(20)
rms
W
30 – 87
30 – 87
W
7 – 67
7 – 67
8
10
12
8.19
10.06
11.96
6.57
8.11
9.57
1.62
1.95
2.38
5.05
5.15
5.01
6.73
8.46
11.29
4.81
6.14
8.14
1.92
2.32
3.15
3.51
3.64
3.58
7.67
9.66
11.48
1.64
2.01
2.51
4.68
4.81
4.57
6.70
8.55
10.99
1.83
2.27
3.02
3.67
3.77
3.64
6.6(16)
6.9(16)
9(16)
23
23
29
-
-
-
15(16)
15(16)
18(20)
15(16)
15(16)
18(20)
15(16)
15(16)
18(20)
21(25)
21(25)
23(25)
22(25)
22(25)
24(25)
30 – 87
35 – 185
35 – 185
7 – 67
7 – 67
7 – 67
IP 21
Chapter 12 |
Technical data
77

Advertisement

Table of Contents
loading

This manual is also suitable for: