LOC
PG
91
25
PARTITION 2 ENTRY/EXIT TIMERS
Segment 1: Entry Time 1
Segment 2: Exit Time 1
Segment 3: Entry Time 2
Segment 4: Exit Time 2
Segment 5 & 6 RESERVED
92
26
PARTITION 3, ACCOUNT CODE
93
26
PARTITION 3, FEATURE AND REPORTING SELECTION
Segment 1
1 =
Quick Arm
2 =
Re-Exit
3 =
Auto Bypass
4 =
Silent Panic
Segment 2
1 =
LED extinguish enable
2 =
Require user code for bypassing zones
3 =
Bypass sounder alert
4 =
AC power/low battery sounder alert
Segment 3
1 =
Open/Close
2 =
Bypass
3 =
Restore
4 =
Trouble
Segment 4
1 =Late to Close / Early to Open
2-8 =Reserved
Segment 5 RESERVED
94
26
PARTITION 3 ENTRY/EXIT TIMERS
Segment 1: Entry Time 1
Segment 2: Exit Time 1
Segment 3: Entry Time 2
Segment 4: Exit Time 2
Segment 5 & 6 RESERVED
95
26
PARTITION 4, ACCOUNT CODE
96
26
PARTITION 4, FEATURE AND REPORTING SELECTION
Segment 1
1 =
Quick Arm
2 =
Re-Exit
3 =
Auto Bypass
4 =
Silent Panic
Segment 2
1 =
LED extinguish enable
2 =
Require user code for bypassing zones
3 =
Bypass sounder alert
4 =
AC power/low battery sounder alert
Segment 3
1 =
Open/Close
2 =
Bypass
3 =
Restore
4 =
Trouble
Segment 4
1 =Late to Close / Early to Open
2-8 =Reserved
Segment 5 RESERVED
97
26
PARTITION 4 ENTRY/EXIT TIMERS
Segment 1: Entry Time 1
Segment 2: Exit Time 1
Segment 3: Entry Time 2
Segment 4: Exit Time 2
Segment 5 & 6 RESERVED
98
26
PARTITION 5, ACCOUNT CODE
40
DESCRIPTION
DEFAULT
0
0
0
0
10-10-10-10-10-10
5 =
Audible Panic
6 =
Auxiliary 1
7 =
Auxiliary 2
8 =
Multi Keypress Tamper
5 =
Enables bypass toggle
6 =
Enables silent auto arm
7 =
Enables auto instant
8 =
Reserved
5 =
Tamper
6 =
Cancel
7 =
Recent Closing
8 =
Exit Error
0
0
0
0
10-10-10-10-10-10
5 =
Audible Panic
6 =
Auxiliary 1
7 =
Auxiliary 2
8 =
Multi Keypress Tamper
5 =
Enables bypass toggle
6 =
Enables silent auto arm
7 =
Enables auto instant
8 =
Reserved
5 =
Tamper
6 =
Cancel
7 =
Recent Closing
8 =
Exit Error
0
0
0
0
10-10-10-10-10-10
PROGRAMMING DATA
_
_
_
_
_ _ _ _ _ _
_
_
_
_
_ _ _ _ _ _
_
_
_
_
_ _ _ _ _ _
NX-8V2 Control
Need help?
Do you have a question about the NetworX Series and is the answer not in the manual?
Questions and answers