Redundant Power Supply (Rps) Cable - D-Link DGS-3000-10TC Hardware Installation Manual

Dgs-3000 series layer 2 managed gigabit ethernet switch
Table of Contents

Advertisement

DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch Hardware Installation Guide

Redundant Power Supply (RPS) Cable

When connecting the Switch to a Redundant Power Supply, an RPS cable is necessary. Please review these products
for matching cable pin assignment.The following diagrams and tables show the DPS-CB150-2PS
receptacle/connector and their pin assignments.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Figure B- 3. DPS-CB150-2PS Cable
RPS 14-pin to two 2-pin DC Power Cable Pin Assignments
2-pin
GND
+12V
-
-
-
-
-
-
-
-
-
-
-
-
39
14-pin
GND
NC
+12V
+12V
+12V
+12V
GND
GND
Power Good
Power Present
NC
NC
GND
GND