Q. LINT DRAWER SWITCH
The lint drawer switch is located in the lint compartment and attached
to the side of the lint drawer track. The lint drawer switch insures that
the dryer will operate only when the lint drawer is completely closed.
This is a safety device and should never be disabled.
R. COMPRESSED AIR REQUIREMENTS
The dryer requires an external supply of air (2.5 cfm @ 80 PSI [0.07 cmm @ 0.68 bars]) on the steam models,
the air is necessary to operate the damper system. On both steam, as well as the gas model, the air is necessary/
required for the blower air jet operation...to clean lint from the impellor/fan (squirrel cage type).
S. REVERSING REAR CONTROL PANEL ASSEMBLY
(AS OF JANUARY 1, 1995)
This panel contains your arc suppressor (A.S.) board, blower contactor,
blower overload, and your forward reverse contactor. It also contains
your 4-position terminal block and your step down transformer.
T. REVERSING REAR CONTROL PANEL ASSEMBLY
(PRIOR TO JANUARY 1, 1995)
This panel contains your arc suppressor (A.S.) board, blower contactor,
and your forward reverse contacor. It also contains your 4-position
terminal block.