13. Select the lowest five PIDS from above, and again view their voltage readings using the BAT_MV PID.
Record their voltage readings.
BATTERY VOLTAGE READINGS
Battery #
14. Select the lowest three readings from the modules above.
BATTERY VOLTAGE READINGS
Battery #
Module Replacement Criteria
If the lowest voltage battery is 0.1 less than the second lowest voltage battery, replace the lowest voltage
battery module.
If the second lowest voltage battery is more than 0.08-volts less than the third lowest voltage battery, replace
the second lowest voltage battery.
Prior to replacing the module, verify the serviceability of the battery's sense lead (measure for resistance of
30.9 K ohms), and verify the module's voltage reading with a DVOM.
Sense Lead Criteria
If two adjoining modules are indicating incorrectly, the sense lead should be suspected and its resistance
should be measured.
Resistance specification is 30.9 K ohms.