1998 Ranger EV New Model Training
Return the vehicle to the repair facility.
Actuate heater/defroster mode on high fan and leave on headlamps
to discharge battery pack.
When battery pack reaches 10% SOC, view BAT_MV PID for
each of the 39 battery modules.
Using the BAT_MV PID, record the battery voltage on the Battery
Voltage Record Sheet. (A copy is provided on the next page. There
is also a copy included as part of Worksheet L, and another copy
that can be found in the Diagnostic Information Appendix.)
Select the five lowest voltage battery modules.
Return to the BAT_MV PID and record the voltages of the five
lowest voltage battery modules.
From these five, compare the voltage readings of the lowest three
battery modules.
If the lowest voltage battery is 0.1 less than the second lowest
voltage battery, replace the lowest voltage battery module.
If the second lowest voltage battery is more than 0.08 volts less
than the third lowest voltage battery, replace the second lowest
voltage battery.
Prior to replacing the module, verify the serviceability of the
battery's sense lead (measure for resistance of 30.9 K ohms), and
verify the module's voltage reading with a DVOM.
LESSON 5: DIAGNOSIS
5-47