LESSON 3: SAFETY AND EMERGENCY INFORMATION
30. Welding on an EV requires special procedures. Damage to
components can result if improper practices are used. Consult
with your supervisor to determine the correct procedure for your
specific application.
31. When performing a visual inspection, check for damaged wiring.
This includes exposed copper; damaged insulation; pinched, cut,
or bare cables, and damaged or crushed connectors.
32. Inspect tools and equipment for cracked, worn, or missing
insulation. If you believe that a tool or piece of equipment is
improperly insulated, repair or replace it; do not take a chance.
33. Have wooden reach poles situated around the areas where
personnel will be working with high voltage equipment. These
can be used to move energized electrical wires from harm's way.
34. Know where the fire extinguishers, reach poles, and other safety
equipment are located when working on or observing an EV.
Be aware of your surroundings.