Table 20-4 shows the maximum number of dense volumes, snapshot copies, LUNs, and
vFiler units that are supported for NDU.
Table 20-4 Maximum limits for NDU
Data ONTAP
Dense
volumes
7.3.x to 8.0
100
7.3.x to 8.0.1
300
7.3.x to 8.1
300
8.0 to 8.0.x
300
8.0.x to 8.1
500
8.1 to 8.1.x
500

20.1.5 Prerequisites for a system NDU

The following sections describe the tasks that must be completed before a major or minor
system NDU is performed.
Reading the latest documentation
Review the Data ONTAP Upgrade Guide for the version to which you are upgrading, not the
version from which you are upgrading. These documents are available on the IBM NAS
Support site, which is available at:
http://www.ibm.com/storage/support/nas/
Verify that the system and hosts (if applicable) fulfill the requirements for upgrade.
Review the release notes for the version of Data ONTAP to which you are upgrading. Release
notes are available on the IBM Support site.
Review the list of any known installation or upgrade problems for both the version of Data
ONTAP to which you are upgrading, and all host-specific items if your environment uses FCP
or iSCSI.
Validating the storage controller system configurations
Confirm that both storage controllers are prepared for the NDU operation. Validate each
individual controller's configuration to identify any issues before upgrading.
Create a detailed upgrade test procedure document and a back-out plan.
Identify any inconsistencies between the two storage controllers within the HA pair controller
configuration so that all identified issues can be corrected before beginning the upgrade.
Removing all failed disks
Failed disk drives prevent giveback operations and can introduce stack and loop instability
throughout the storage system. Remove or replace all failed disk drives before beginning the
system NDU operation.
286
IBM System Storage N series Hardware Guide
Snapshot copies
FC, SAS
SATA
storage
storage
500
500
12,000
4,000
12,000
4,000
12,000
4,000
20,000
20,000
20,000
20,000
LUNs
vFiler units
FC, SAS
storage
2,000
64
2,000
64
2,000
64
2,000
64
2,000
64
2,000
64
SATA
storage
5
5
5
5
5
5