Replacing Sas Cables In A Multipath Ha Configuration - IBM N series Hardware Manual

System storage
Hide thumbs Also See for N series:
Table of Contents

Advertisement

c. Compare the firmware information in the command output with the disk shelf firmware
information at the IBM N series support site to determine the most current disk shelf
firmware version.
13.The next step depends on how current the disk shelf firmware is:
– If the firmware version in the command output is the same as or later than the most
current version on the N series Support Site, no disk shelf firmware update is needed.
Complete Steps 14 and 15.
– If the firmware version in the command output is an earlier version than the most
current version on the N series Support Site, you must update the disk shelf firmware.
Complete Steps 14 - 16.
14.Configure the system and enable licenses as needed by using the information about
configuring an HA pair in the Data ONTAP High Availability and MetroCluster
Configuration Guide for 7-Mode.
15.Boot the storage system and begin setup.
16.In Step 13, if you had an earlier version of disk shelf firmware than the most current
version on the N series Support Site, download the new disk shelf firmware file.

9.2.3 Replacing SAS cables in a multipath HA configuration

You can nondisruptively replace SAS cables in a multipath HA configuration. The SAS cables
that are described in this section include SAS copper and SAS optical cables.
When you replace SAS cables, consider the following important points:
Replacing a SAS cable means that you are replacing a cable by using the same ports for a
controller-to-shelf or shelf-to-shelf connection.
Situations where you might want to replace a SAS cable can include when a cable fails, a
longer cable is needed, or SAS optical cables are preferred instead of SAS copper cables.
Important: After your storage system is up and serving data, you cannot move SAS
cables (change the SAS ports to which a cable is connected) nondisruptively. If you
must correct system cabling, you can use a maintenance period to do so.
Disk shelves that are connected with SAS optical cables require a version of disk shelf
firmware that supports SAS optical cables.
Best practice is to update all disk shelves in the storage system with the latest version of
disk shelf firmware.
Note: Do not revert disk shelf firmware to a version that does not support SAS optical
cables.
You cannot change any disks, disk shelves, or components of a controller module as part
of these procedures.
Complete the following steps to replace SAS cables:
1. Verify that your stretch MetroCluster system is Multi-Path HA by running the following
command at the console of both controllers:
sysconfig
Chapter 9. MetroCluster expansion cabling
135

Hide quick links:

Advertisement

Table of Contents
loading