Cross Zone Police Code Reporting

The panel will transmit the Cross Zone Police Code reporting code, if programmed, when two different zones are
violated within the same armed-to-armed period.
The Burglary Verified Timer, if programmed, will start when a zone is violated and cause an alarm. If a second zone is
violated before the timer expires, the panel will transmit the Cross Zone Police Code reporting code. If the timer expires
before a second zone is violated, the panel will not send the reporting code, and the timer will start again. Valid entries for
the Burglary Verified Timer are 000-255 minutes (000 to disable).
The Double Hit option allows the Cross Zone Police Code reporting code to be sent when two zone alarms occur on the
same zone. The Burglary Verified Timer, if programmed, also applies to the Double Hit option. Only zones programmed
as Interior, Interior Delay, Interior Stay/Away, or Delay Stay/Away are included in the Double Hit option.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Cross Zone Police Code ........................................ Section [328]
Burglary Verified Timer ........................................... Section [172]
Double Hit ............................................................... Section [017], option [4]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.7.4

Delinquency Reporting

The Delinquency feature is used to monitor system activity. When the Delinquency Transmission Delay timer
expires, the panel will transmit the Delinquency reporting code.
If the system is programmed to monitor Activity Delinquency, the timer will be programmed in hours. The timer
will start under the following conditions:
• When the system is armed in the Stay mode
• When the system is disarmed
• When a zone is violated and restored while the system is disarmed/Stay armed (Interior, Interior Delay, Interior
Stay/Away, or Delay Stay/Away zones only).
The activity delinquency timer will be ignored when the system is armed in the Away mode. Zones that are
bypassed in the [✱][1] Bypass menu will not reset the timer.
If the system is programmed to monitor Closing Delinquency, the timer will be programmed in days. The timer
will restart every time the system is disarmed.
When the Daylight Savings Time option is turned on, if the Delinquency Transmission Delay timer is
programmed for 1 hour (Activity Delinquency only), then the panel will send a Delinquency reporting code
at 2:00am on the last Sunday in March.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Activity/Closing Delinquency .................................. Section [380], option [8]
Delinquency Transmission Delay ........................... Section [370]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.7.5

Maintenance

The panel will transmit a Battery Trouble Alarm Reporting Code when the backup battery drops below 11.5 V
Battery Trouble Restoral reporting code will not be transmitted until the battery has been charged over 12.5 V
To prevent the panel from transmitting an AC Failure Trouble Alarm reporting code during short power outages the
panel will not send the signal unless AC power is lost for the number of minutes programmed for the AC Failure
Communication Delay. The AC Failure Trouble Restoral reporting code will be transmitted once AC power has been
restored for the amount of time programmed for AC failure.
NOTES: If AC Failure Communications Delay is programmed as 000, the AC Failure Trouble reporting code will
be sent immediately. For proper communication of PC5204 AC Troubles, program the AC Failure Communictaion
Delay as "000".
A Bell Circuit Trouble Alarm reporting code will be transmitted immediately if an open condition is measured on the bell
output of the main panel. The Bell Circuit Trouble Restoral reporting code will be transmitted as soon as the problem is
corrected.
A Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on any Fire
zone (see Section 5.1 "Zone Definitions" ) . The Fire Trouble Restoral reporting code will be transmitted as soon as the
problem is corrected.
The Auxiliary Power Supply Trouble Alarm reporting code will be transmitted if the AUX output is shorted. The AUX
output control incorporates a fuseless design. When excessive current is drawn the panel will automatically shut off the
output. The panel will constantly check the AUX output and when the excessive current draw is removed the panel will
reset the output and transmit an Auxiliary Power Supply Trouble Restoral reporting code.
A TLM Trouble reporting code can only be transmitted if a GSM1000/LINKS2X50 communicator is being used (see Section
5.28 "GSM1000 Cellular Communicator") . The panel will only transmit the signal after the time programmed for the TLM
Trouble Delay. The TLM Restoral reporting code will be transmitted immediately once the trouble is restored.