Event Buffer

The panel will store the last 256 events that have occurred on the system. Each event will contain the time, date,
partition and the event itself along with the zone number, access code number or any other information
pertaining to the event.
If the Event Buffer Follows Swinger Shutdown feature is enabled the event buffer will not store events after
the swinger shutdown level has been reached. This will prevent the panel from overwriting the entire buffer if a
problem exists. (see Section 5.18 "Swinger Shutdown". )
The event buffer can be viewed three different ways. It can be viewed through an LCD keypad, printed on-site
using the PC5400 printer module or it can be uploaded through the DLS software.
5.17.1

Viewing the Event Buffer

The following is the procedure for viewing the event buffer through the LCD keypad:
Step 1 - Enter [✱] [6] [master code]
Step 2 - Select 'View Event Buffer'
The keypad will display the event number, partition, time and date of the event in question. Use the [✱] key to toggle
between this information and the event itself. Use the arrow keys (<>) to scroll through the events in the buffer.
When you have finished viewing the event buffer press the [#] key to exit.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Event Buffer Follows Swinger Shutdown ............... Section [013], Option [7]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.18

Swinger Shutdown

The swinger shutdown feature is designed to prevent a runaway communicator from tying up the central station.
Different limits can be programmed for Zone Alarms
has communicated the programmed number of transmissions for an event it will no longer report that event until
the swinger shutdown is reset.
For example, the swinger shutdown limit for zone alarms is set to [003]. The panel will not send more than 3 alarm
signals for each zone with a swinger attribute until the swinger shutdown is reset.
The bell output will not be activated for alarms on zones that have exceeded the limit of alarms set in the Swinger
Shutdown counter.
Swinger Shutdown will be reset when the panel is armed or every day at midnight. Once reset, the panel will again
communicate normally.
Maintenance alarms and restorals will only be reset at midnight (not after arming).
Programmable outputs programmed with options (23) Silent 24 Hour and (24) Audible 24 Hour do not
follow Swinger Shutdown
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Swinger Shutdown Limit (Alarms/Tampers/Maintenance)
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.19

Daylight Savings Time

If the Daylight Savings Time option is enabled, the panel will follow the Daylight Savings Time change. At 2 :00 am.
on the last Sunday in March, the panel clock will be set forward one hour to 3:00 am. At 2:00 am. on the last Sunday
in October, the panel clock will be set back one hour to 1:00 am.
Events programmed to occur between 2 and 3 a.m. will not occur on the last Sunday in March. Events programmed
to occur between 1 and 2 a.m. will occur twice on the last Sunday in October.
When the Daylight Savings Time option is turned on, if the Delinquency Transmission Delay timer is pro-
grammed for 1 hour (Activity Delinquency only), then the panel will sent a Delinquency reporting code at
2:00am on the last Sunday in March.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Daylight Savings Time ............................................ Section [017], option [6]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.20

Keypad Backlighting

The keys of all the keypads can be backlit to provide easy viewing in dim lighting conditions. If the Keypad
Backlighting Option is enabled the keys will be illuminated.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Backlighting Option ................................... Section [016], Option [5]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.21
Arming / Disarming Options
If the Arm/Disarm Bell Squawk option is enabled the panel will squawk the alarm output once upon arming and
twice upon disarming. The Opening After Alarm Keypad Ringback option will give you the ability to beep the
keypad 10 times rapidly if the panel is disarmed after an alarm occurred. The Opening After Alarm Bell
Squawk option will give you the ability to squawk the bell output 10 times rapidly if the panel is disarmed after
an alarm occurred.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly after the Closing reporting code
has been successfully transmitted to the central station.
If the Bypass Status Displayed While Armed option is chosen, the Bypass light will be ON while the system is
armed to indicate that there are bypassed zones.
R
A
M
D
Zone Alarms, Zone Tampers
Zone Alarms
Zone Alarms
Zone Alarms
E
S
C
R
I
Zone Tampers and Maintenance
Zone Tampers
Zone Tampers
Zone Tampers
Maintenance
Maintenance
Maintenance signals. After the panel
Maintenance
Section [370]
35