Typical setup with tripod is
described here.
You can also use a fixed-
height tripod.
4.

Running a Static Survey

Equipment Setup

The equipment setup instructions are the same for both the
base and the rover. Install and run the base first.
In both cases, the installation site should offer the best pos-
sible GPS reception conditions. The antenna should have a
clear view of the sky in all directions. There should be no, or
a minimum of satellite obstructions in the vicinity.
1. Set up the tripod / tribrach combination over the point.
2. Attach the vertical extension bar and a tribrach adapter to
the GNSS antenna.
3. Place the GNSS antenna assembly on the tripod.
4. Place the ProMark3 receiver into the field bracket.
5. Attach the field bracket / ProMark3 combination onto the
tripod.
6. Connect the GNSS antenna cable to the unit.
7. Measure and record the instrument height (HI) of the
GNSS antenna.
6.
1.
7.
2.
3.
5.
H Vertical
H Slant
43