WARNING
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
Perform the following steps to reinstall the
water recirculation pump:
1.
Connect the end of the water inlet fill tube
to the recirculation pump.
2.
Mount the recirculation pump to the unit
with its three 9/32" mounting screws.
3.
Reinstall the ice making component hous-
ing and evaporator in their proper loca-
tions and install the screws.
4.
Connect the recirculation pump 3-wire
connector.
5.
Install a wire tie around the 3-wire connec-
tor.
6.
Reinstall the green ground wire with its
mounting screw.
REASSEMBLY NOTES:
• Be sure to route the water recirculation
pump wire cable toward the back of the unit
and behind the water inlet fill tube.
• Be sure to fit the water inlet fill tube inside the
molded retainer, as shown below.