Excell SK-VET Service Manual page 22

Weighing scale
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD
Press the
key
TARE
Use the
key to
ON/ZERO
enter a parameter
Press the
key
TARE
Refer to NOTE 4 to key in
parameters and then press
the
key
TARE
= Hold function disabled.
= "Peak hold" mode (
The scale shows the maximum weight value detected from the continuously changing
weight values. Press any key to exit the hold function.
= "Stable hold" mode 1 (
When the scale becomes stable, the display shows the current weight value. Press any key
to exit the hold function.
= "Stable hold" mode 2
When the scale becomes stable, the display shows the current weight value. Re-zero the
scale (weight below 10d) to exit the hold function.
= "Animal Weighing " mode
Refer to NOTE4 to key in the stabilization range and timer parameters. When the scale
becomes stable, the display shows the current weight value. Re-zero the scale (weight
below 10d) to exit the hold function.
SK-VET V1.0
Cont.
Back to the weighing
mode
active when the weight on platter is over 10d)
.
Hold function setting
LCD displays the last current setting
Hold function setting
Use the
ON/ZERO
Default setting = 0
0 ⇒ Hold function disabled
1 ⇒ "Peak hold" mode
2 ⇒ "Stable hold 1" mode
3 ⇒ "Stable hold 2" mode
4 ⇒ "Animal weighing" mode
If
NOTE 4 to key in parameters
active when the weight on platter is over 10d)
active when the weight on platter is over 10d)
(active when the weight on platter is over 10d)
20
key to key in a parameter
parameter setting
is selected, refer to
SME300000067