These functions help you with various settings of the
TM-D1000.

14.1Footswitch (REMOTE CONT)

The footswitch connected to the rear of the TM-
D1000 can be used to step through the snapshot
memories, either forwards or backwards. It can also
be used to perform punch-in and punch-out opera-
tions on the unit controlled via MMC.
1
Press and hold down the
press the
key.
OPTION
2
Turn the
DATA ENTRY
tom line of the display shows
and press
.
ENTER
3
Turn the
DATA ENTRY
tom line of the display shows
CONT Function
R E M O T E
C O N T
S N A P S H O T
C h a n g e [
4
Turn the
DATA ENTRY KNOB
SNAPSHOT Change [
between
up ]
SNAPSHOT Change
,
[down]
Remote Punch
and
In/Out
. Press
ENTER
setting.
NOTE
Always use a TASCAM RC-30P footswitch or
equivalent. If you are in any doubt as to the
kind of footswitch you should use, contact
your TASCAM dealer.

14.2Meter settings

The "fall" time of the meter, as well as the peak hold
time, can be set from the System menu.
Option
System
Adjust
M e t e r
A d j u s t
R e l e a s e
1
Use the
DATA ENTRY
30 ms
between
,
key, and
SHIFT
knob until the bot-
System
,
knob until the bot-
REMOTE
, and press
ENTER
:
F u n c t i o n
u p
]
to choose
to confirm your
Meter
Ã
T i m e : 3 0 m s
knob to choose
60 ms
90 ms
and

14 - Miscellaneous functions

2
Push the
DATA ENTRY
Peak Hold Time
M e t e r
A d j u s t
P e a k
3
Turn the
DATA ENTRY
peak hold time between
1.0
seconds in 100 ms steps.
These meter settings are only effective when
digital signals only are being monitored (i.e.
the EXT IN switch is not pressed—see 8.1.1,
"EXT IN").

14.3LCD contrast

As well as the method of adjusting the LCD contrast
described on page 6, you can also use the menu
system:
Option
System
Contrast
L C D
C o n t r a s t
> > > > > > > > É
Turn the
DATA ENTRY
contrast until it is at a comfortable viewing angle.

14.4Battery levels

The lithium batteries in the TM-D1000 provide
backup for your settings and should last for a number
of years before they need to be replaced.
However, as with all batteries, there is a possibility
that they may start to leak after about three years,
even if the voltage is within permissible limits. We
therefore suggest changing the battery every three
years or thereabouts.
If the battery drops below the critical level, the
display will show:
W a r n i n g !
B a t t e r y
.
TASCAM TM-D1000 Operations Manual
knob to enter the
screen:
H o l d
T i m e : 0 . 0 s
knob to adjust the
0.0
seconds and
NOTE
LCD
É
É
É
É
É
É
É < < < < < < < <
knob to adjust the screen
NOTE
E m p t y
36