OPTIONAL THERMOSTAT OPERATION

The Room Heater is designed so that it can be operated by a wall mounted thermostat. This option is not provided
directly from the factory, but can be purchased from your dealer or the Bixby website (www.bixbyenergy.com) or
any other "on/off" 24V AC wall mounted thermostat can be used. Do not use a powered thermostat to avoid
damage to the Room Heater. Follow the the thermostat installation instructions carefully.
NOTE:
Thermostat should be mounted on an inside wall and not in direct line with the Room Heater
convection air. A prefered location would be on an inside wall opposite the Room Heater.
When the thermostat is hooked up and calling for heat, the Room Heater will display the currently selected level
using the LEDs. If the thermostat is NOT calling for heat, the currently selected level will be displayed, but all
the LEDs will be slowly flashing in unison and the Room Heater run at level 1.
THERMOSTAT INSTALATION INSTRUCTIONS
1.
Unplug the Room Heater.
2.
Remove the left side panel.
3.
Locate the Trim Pot / Thermostat bracket.
4.
Loosen the middle two screws on the thermostat
block and remove the metal jumper.
5.
Run the wire for the thermostat through the
black grommet on the back panel.
6.
Attach the wires of the thermostat to the two
terminals.
7.
Replace the side panel.
2020866 REV A
Thermostat connection
FEED
EXHAUST
FAN
RATE
- 0 +
- 0 +
3
3
3
3
5
5
5
5
FUEL
��������
CORN
WOOD
Figure 2