SPECIFICATIONS

Fuel:
Multi-fuel System: Dry shelled corn, Wood Pellets (recommended maximum size approximately ¼ in. diameter x 1¼ in.
long), or "BIXBY" certified Blue or Green Biomass pellets. The use of "cracked corn" is not recommended due to feed and
burn issues. The use of lower quality corn with foreign material (cobs, stones, or other material) may cause feed issues. In
addition, the use of seed corn is not recommended due to the coating interfering with the operation of the Room Heater. When
loading the corn into the hopper, remove as much foreign material as possible. See Operating Instructions (page 21) for more
information.
Heating Area:
Installation:
Shipping Weight:
Electrical:
Dimensions:
Fuel Hopper Capacity: 2.4 cu. ft. (approx. 106 lbs. shelled corn)
Listing:
4
Level
Approx. Feed Rate
lbs/hr (kg/hr)
1
1.8 (0.8)
2
2.1 (1.0)
3
2.3 (1.1)
4
2.6 (1.2)
5
3.0 (1.4)
6
3.5 (1.6)
7
3.9 (1.8)
8
4.6 (2.1)
*Assumes running at a single level, actual time will vary as the burn level changes,
starting and shutting down, and trim knob adjustments.
Varies depending on floor plan, heat loss, geographic location, altitude, heater venting configuration, moisture
content of fuel and climate.
Install in accordance with "BIXBY" instructions and local building codes.
380 pounds (172 kg)
120 VAC, 60 Hz., 15 amp Service Required, dedicated line recommended
Start: 10 Amps
Run: 2 Amps
Height = 33 in (838 mm)
Width = 28 in (711 mm)
Depth = 30 in (762 mm)
The Bixby MaxFire
Multi-Fuel Room Heater was tested by OMNI-Test Laboratories, Beaverton, Oregon
TM
to ASTM E1509 and ULC C1482 (report number 223-S-06-2). Emission tests were also conducted per the
USA Environmental Protection test methods 28A and 5G for particulate emissions. The Max-Fire
under 40 CFR 60.531, therefore the results have not been submitted to the EPA.
The results are as follows:
Category 1 (low burn)
Category 2 (medium low burn)
Category 3 (medium high burn)
Category 4 (high burn)
Overall weighted average
Time Between
Approximate Hours/
Ash Dumps *
21 hrs
17 1/2 hrs
16 hrs
14 hrs
12 1/2 hrs
10 1/2 hrs
9 1/2 hrs
8 hrs
2.3 grams per hour (.081 ounces)
2.0 grams per hour (.070 ounces)
2.42 grams per hour (.085 ounces)
2.21 grams per hour (.077 ounces)
2.25 grams per hour (.079 ounces)
Full Load *
57
48
43
38
34
29
26
22