LEVELING THE ROOM HEATER

CAUTION:
THE ROOM HEATER SHOULD BE LEVELED BEFORE ATTACHING THE VENT PIPE.
The supplied bulls eye level can be used to level the Room Heater front-to-back and side-to-side, a 6 in.
level may also be used.
1.
Place the level centered side-to-side and about 4 in. (10cm) back from the front of the Room Heater on the
top surface. The bubble should end up centered inside the middle circle on the level. If the bubble is not
in that position, the bubble will be towards the high side of the Room Heater. See Figure 3.
2.
Locate the leveling feet on the bottom of the Room Heater. See Figure 4.
3.
Lift the Room Heater near the foot to be raised (low side, opposite the bubble on the level). A pry bar can
be used to lift the Room Heater with a wooden shim or something similar to protect the hearth pad.
4.
With the corner of the Room Heater elevated, place a piece of wood (or other blocking) under the Room
Heater to hold it while adjusting the leg. The leg length should be adjusted by hand, but if needed a wrench
maybe used. This will not work if the foot is turned all the way in, as that portion will not be accessible.
5.
Remove the block using the prybar and check adjustment.
6.
Proceed to adjust the feet until the bubble is centered inside the inner circle. This is a very important step
as the feed system is gravity fed and it will ensure that the fuel is fed into the burn pot correctly.
Bulls Eye Level
4"
Figure 3
8
Leveling
Legs
Figure 4
2020866 REV A