EXHAUST FAN

CAUTION:
Unplug the Room Heater from its power
source before cleaning the impeller.
To access this component, open Right Side Panel, and remove
the fan cover. Using a brush and a vacuum, clean the impeller.
Inspect gasket. If it is torn, replace gasket before placing unit
in service.
This cleaning should be performed once a year.

CLEANING THE EXHAUST MANIFOLD

The Exhaust Manifold should be cleared on a yearly
basis to ensure proper air flow in the Room Heater.
1. Turn off the Room Heater and allow to completely
cool (minimum of 2 hours).
2. Remove the back panels (see previous page for
instructions).
3. Move the cleaning levers up and down several times
until they move freely.
4. Using a shop vac, clean the ash around the base of
the tubes.
5. Use the Exhaust Manifold Cleaning Kit (available at
your dealer) to clean in behind the tubes.
6. Replace the heat exchanger cover plates.
26
Figure 31
Clean this area
Figure 32
Fan Cover
2020866 REV A