VENTING INSTALLATION AND INSTRUCTIONS

WARNING:
A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE
UTMOST IMPORTANCE THAT THIS VENT SYSTEM BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.

VENT SYSTEM APPROVALS

BIXBY DIRECT VENT PIPE is listed by OMNI-Test Laboratories, Inc. as a vent for BIXBY pellet and corn Room
Heaters only. NO OTHER PIPE IS LISTED FOR USE WITH BIXBY ROOM HEATERS. The use of non-Bixby
vent pipe will void the Room Heater's warranty. The minimum clearance from this vent to combustible materials
is 2 in. (50mm). Combustible materials include but are not limited to lumber, plywood, sheetrock, plaster and lath,
furniture, curtains, electrical wiring, and building insulation of any kind. Never fill any required clearance space
with insulation or any other materials.
This vent is tested and listed by OMNI-Test Laboratories, Inc. to UL Standard 641 and to ULC/ORD-C441
(Canada) for safe low temperature venting systems, Type L, and produced under the factory inspection and follow-
up program of OMNI-Test Laboratories, Inc.
NEVER INSTALL SINGLE-WALL PIPE TO THE Room Heater.
NOTE:
Proper planning for your vent installation will result in greater safety, efficiency, and convenience, saving both
time and money. Use only authorized BIXBY ENERGY SYSTEMS, INC. listed parts. Do not install damaged
parts.
TOOLS AND EQUIPMENT
Level (a six inch level is recommended)
Eye protection
Hammer
Screwdriver
Tape measure
High temperature waterproof sealant (min 500F)
Saber or keyhole saw
Stud finder
Adjustable wrench
Gloves
CAUTION: The Room Heater should be leveled before attaching the vent pipe. See page 8 for leveling
information.
2020866 REV A
9