BOULTER BUDERUS CAMRAY 5 PAGE 44

8:2 AIR SHUTTER ADJUSTMENT

The Burner has a fixed Air Shutter with manual adjustment.
To adjust the CO
at the Air Shutter use a 3mm allen key as shown. To increase the setting turn the airshutter
2
clockwise (+) and to decrease turn anticlockwise (-).
Fig. 8:2a Air Shutter Adjustment

8:3 BAFFLE ARRANGEMENT