The Camray 5 And Camray 5 Utility; Optional Timer/Programmer (White Kitchen Model Only) - Boulter Camray 5 Installation & Maintenance Manual

Boulter camray 5 oil fired boilers
Table of Contents

Advertisement

Please also note that on conventional flue models, it is possible for the air intake at the rear of the Boiler
casing to become blocked with household debris. This air intake must remain clear at all times and so it is
advisable to inspect and clean this area regularly. Please refer to
Flue Terminal Pluming
Due to the high efficiency of the Camray 5 range white water vapour from the flue discharge - called pluming
may be observed from time to time under certain weather conditions. This is perfectly normal and should be
no cause for concern.
1:5.11.2 FAILURE TO START
If the Burner fails to start, adopt the following procedure:
1. Check that there is oil in the tank and that the supply valve is open.
2. Check the programmer or time switch to ensure that it is operating and set to the correct time to be "ON".
3. Check that the Boiler Control Thermostat is set high enough to be "ON" or calling for heat.
4. Check that the Burner indicator is lit. (Camray 5 kitchen model.)
5. Check whether the limit indicator on the control fascia is glowing,
Press the reset button once the temperature has dropped sufficiently.
6. Check whether the red LOCKOUT indicator
Burner Control box are glowing. This indicates that the Burner has attempted to start but has not fired
successfully. Press the reset button on the Control box, when released, the lights will go out and the Burner
will again attempt to start. If the Burner does not run and again goes to lockout with red indicators glowing:
Wait three minutes.
Repeat the procedure by pressing the button.
Failure to start on the second attempt indicates a fault requiring attention.
Switch off the mains supply and call your service engineer.
1:5.12 OPTIONAL TIMER/PROGRAMMER (WHITE CASED KITCHEN MODEL ONLY)
An optional timer/programmer kit is available as a plug-in extra for the concealed Control Panel. This
facilitates full control over hot water and heating requirements. Part No. EL47034C
Refer to
Section
4:11.
This programmer must only be fitted by a qualified electrical engineer/installer
BOULTER BUDERUS CAMRAY 5 PAGE 5
2:1 INTRODUCTION
This Manual covers Installation, Commissioning and Maintenance of the Camray 5 and Camray 5 Utility
Boilers.
The Camray 5 and Camray 5 Utility are:
1. Designed for Central Heating and Hot Water.
2. Suitable for conventional open vented Central Heating systems.
file://D:\PL47000\PL47000.htm
section 1:2.2
if so it indicates an overheat situation.
on the Control Panel (Camray 5 Kitchen Model) and
Page 10 of 67
in this booklet.
14/04/2005

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Boulter Camray 5

Table of Contents