York HA090 Technical Manual page 148

Split-system air-cooled condensing units
Table of Contents

Advertisement

TABLE 15: SUPPLY AIR PLENUM PERFORMANCE DATA
Face
0
Model
CFM
Velocity
SPREAD
(FPM)
Throw
(Feet)
Min.
Max.
1600
630
38
1800
710
43
060
2000
790
48
2200
870
52
2400
940
57
2400
615
47
2700
690
53
090
3000
770
59
3300
845
65
101
3600
920
71
110
3200
820
63
3600
920
71
110
120
4000
1025
78
123
4400
1130
86
135
4800
1230
94
147
4800
880
84
132
5400
1000
95
149
180
6000
1110
106
165
6600
1220
116
182
7200
1330
126
199
1. Adjusting the vertical louvers will vary the throw, the spread and the drop.
2. Adjusting the horizontal louvers will only vary the drop.
3. The velocity of the air will be 125 ft./min. at the minimum distance and 80 ft./min. at the maximum distance.
4. The velocity of the conditioned air at the bottom of the drop will be 50 ft./min. Drafts will occur if the drop extends into the occupied
level of the conditioned space.
TABLE 16: BLOWER MOTOR AND DRIVE DATA
MOTOR
BLOWER
MODEL
RANGE
HP
FRAME
(RPM)
060
810/1110
3/4
090
655/880
1-1/2
120
700/950
2
180
625/810
3
14
http://www.rezine.net
Vertical
Horizontal
1
2
Louvers
Louvers
(Plan
(Elevation
View)
View)
Spread
3
0
(Feet)
SPREAD
18
4
Min. Max
Drop (Feet)
59
13
20
15
8
67
14
22
16
8
74
16
25
16
9
81
17
27
16
9
89
19
30
17
9
74
20
29
19
9
83
22
32
20
10
92
24
35
21
10
26
38
21
10
28
41
22
11
98
25
37
21
10
28
41
22
11
30
45
22
11
33
49
23
12
35
53
23
12
32
48
23
12
36
54
24
12
39
59
25
13
43
65
26
13
46
70
27
14
ADJUSTABLE MOTOR PULLEY
OUTSIDE
PITCH
DESIG-
DIA.
DIA.
NATION
(IN.)
(IN.)
56
1VL44
3.1-4.1
2.8-3.8
56
1VL44
2.1-4.1
2.8-3.8
56
1VL44
3.1-4.1
2.8-3.8
56
1VM50
3.7-4.7
3.4-4.4
Angle of Deflection
Vertical
Horizontal
Louvers
Louvers
22-1/2
(Plan
(Elevation
SPREAD
View)
View)
Throw
Spread
(Feet)
(Feet)
0
SPREAD
Min.
Max
Min. Max
Drop (Feet)
27
43
12
19
14
30
48
14
22
14
34
53
15
24
14
37
58
17
26
15
41
64
18
29
15
34
53
23
33
17
39
59
25
36
18
42
66
27
40
19
46
73
29
44
19
50
79
32
47
20
45
70
29
43
19
50
79
32
47
20
56
88
35
52
20
62
97
38
57
21
68
106
41
62
21
61
95
38
56
21
68
107
42
63
22
76
119
46
69
23
84
131
50
76
23
92
143
55
83
24
FIXED BLOWER PULLEY
OUTSIDE
BORE
DESIG-
DIA.
(IN.)
NATION
(IN.)
5/8
AL64
6.2
7/8
AK79
7.9
7/8
BK80
7.4
7/8
BK105
9.9
Page 148
246668-YTG-B-0906
Vertical
Louvers
45
(Plan
SPREAD
View)
Throw
Spread
(Feet)
(Feet)
18
Min.
Max.
Min. Max.
7
21
32
33
48
7
23
37
35
56
8
25
40
38
60
8
29
44
44
66
8
30
48
45
72
8
26
39
45
65
9
29
45
48
71
9
32
50
52
78
9
35
55
56
85
10
38
60
60
91
9
34
53
54
82
10
38
60
60
91
10
42
66
67
102
11
47
73
76
115
11
51
80
85
127
11
46
72
73
112
11
52
81
81
124
12
57
89
90
138
12
63
98
99
152
12
68
107
109
166
BELT (NOTCHED)
PITCH
PITCH
BORE
DESIG-
DIA.
LENGTH
(IN.)
NATION
(IN.)
(IN.)
5.8
3/4
A32
33.3
7.5
1
A36
37.3
7.0
1
A36
37.3
9.5
1
A57
58.3
Unitary Products Group
Horizontal
Louvers
(Elevation
View)
0
18
SPREAD
Drop (Feet)
8
4
8
4
9
5
9
5
9
5
9
5
10
5
10
5
10
5
11
6
10
5
11
6
11
6
12
6
12
6
12
6
12
6
13
7
13
7
14
7
QTY.
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading