o This appliance is not designed to be connected to a combustion
product evacuation device. Particular attention should be given
to the relevant requirements regarding ventilation.
o IMPORTANT: THE FIBRE WASHERS SHOWN IN THE ABOVE
DIAGRAM MUST BE IN PLACE WHEN CONNECTING THE
ADAPTOR ELBOW.
o Connection to the cooker should be made with an approved
appliance flexible connection to BS 669.
o If the cooker has been converted for use with LPG, then it should
be connected to the gas supply using an appropriate bayonet
type hose. The hose MUST be suitable for use with LPG gas,
these are identifiable by a red band or stripe.
o A hose length of 0.9m to 1.25m is recommended. The length of
hose chosen should be such that when the cooker is in situ, the
hose does not touch the floor.
o Care should be taken to ensure that the temperature rise of
areas at the rear of the cooker that are likely to come in contact
with the flexible hose do not exceed 70°C.
o Gas pressure may be checked on a semi-rapid hob burner.
Remove the appropriate injector and attach a test nipple. Light
the other burners and observe that the gas pressure complies
with the gas standards in force.
o This cooker can be connected to the supply both on the right and
left hand side at the rear of the cooker. To reverse the position,
o In compliance with the
manufacturer's installation
instructions, the adaptor elbow
should be connected to the gas
inlet at the rear right corner of
the appliance and pointing in a
downward direction. As indicated
in the diagram opposite.