Alert! Unsupported memory or incomplete
sets in the following bank(s): Bank x
Amount of available memory limited to
256 MB!
Auxiliary device failure
BIOS Update Attempt Failed!
CD-ROM drive not found
CPUs with different cache sizes
detected
Decreasing available memory
Diskette drive n seek failure
Diskette read failure
Diskette subsystem reset failed
ECC memory error
Remote access controller error
Remote access controller is not present
Error: Maximum PCI option ROM count
exceeded!
Gate A20 failure
Hard disk controller failure
Hard disk read failure
I/O parity interrupt at address
size in all banks; faulty
memory module(s).
Memory modules installed
in the specified bank are
not the same type and
size; faulty memory
module(s).
OS Install Mode is
enabled in the System
Setup program.
Loose or improperly
connected mouse or
keyboard cable; faulty
mouse or keyboard.
Remote BIOS update
attempt failed.
Improperly connected or
missing CD drive.
Microprocessors with
different cache sizes are
installed.
Faulty or improperly
installed memory modules.
Incorrect configuration
settings in the System
Setup program.
Faulty or improperly
installed diskette drive.
Faulty or improperly
inserted diskette.
Faulty or improperly
installed diskette drive.
Faulty or improperly
installed memory modules.
Embedded remote access
memory may be
temporarily corrupted.
Too many expansion cards
have ROM enabled in the
System Setup program.
Faulty keyboard controller;
faulty system board.
Incorrect configuration
settings in System Setup
program; improperly
installed hard drive, or
loose interface or power
cable; faulty hard-drive
controller subsystem.
Faulty or improperly
installed expansion card.
properly installed. If the problem persists, see
"Troubleshooting System
"Troubleshooting Your System."
Ensure that all banks contain memory modules
of the same type and size and that they are
properly installed. If the problem persists, see
"Troubleshooting System
"Troubleshooting Your System."
Disable OS Install Mode in the System Setup
program (see "Using the System Setup
program" in the User's Guide).
See
"Troubleshooting the
"Troubleshooting the
Keyboard" in
"Troubleshooting Your System."
Retry the BIOS update. If problem persists, see
"Getting
Help."
See
"Troubleshooting a CD
"Troubleshooting Your System."
Ensure that all microprocessors have the same
cache size and that they are properly installed
(see
"Adding or Replacing a
"Installing System Options").
See
"Troubleshooting System
"Troubleshooting Your System."
Run the System Setup program to correct the
settings (see "Using the System Setup
Program" in the User's Guide).
See
"Troubleshooting the Diskette
"Troubleshooting Your System."
Replace the diskette.
See
"Troubleshooting the Diskette
"Troubleshooting Your System."
See
"Troubleshooting System
"Troubleshooting Your System."
To clear the embedded remote access
memory, shut down the system, disconnect
the power cords, wait approximately 30
seconds, reconnect the power cords, and
restart the system. If the problem persists, see
"Getting
Help."
Disable ROM for some of the expansion cards.
See "Using the System Setup Program" in the
User's Guide.
See
"Getting
Help."
Run the System Setup program to correct the
drive type (see "Using the System Setup
Program" in the User's Guide). If the problem
persists, see
"Troubleshooting Hard
"Troubleshooting Your System."
See
"Troubleshooting Expansion
"Troubleshooting Your System."
Memory" in
Memory" in
Mouse" and
Drive" in
Microprocessor" in
Memory" in
Drive" in
Drive" in
Memory" in
Drives" in
Cards" in

Advertisement

Table of Contents
loading

Table of Contents