Tone_Out; Tone_Mode; Tone_Level - Datavideo AD-100 Instruction Manual

Audio delay box
Table of Contents

Advertisement

N.B. The unit will automatically exit the MENU settings mode if it is left idle for 12 seconds or more.

4. TONE_OUT

This setting switches the TONE_OUT function on or off.
- Press the MENU button to enter the system configuration settings.
- Turn the ADJUST Knob to select TONE_OUT setting.
- The cursor will flash at the beginning of this menu option.
- Press MENU button again to move the flashing cursor to the setting position.
- Turn the ADJUST knob to change the TONE_OUT setting between ON or OFF.
- Press the ADJUST knob in to save or confirm the chosen setting.
- The flashing cursor will return to the beginning of this menu option.
- Rotate the ADJUST knob to choose another menu option or press the mode button.
N.B. The test tone will be output at the level set within the TONE_LEVEL menu option. This test tone will
also override any audio source already being fed through the AD-100.

5. TONE_MODE

This setting allows the 1KHz test tone to be switched on or muted.
- Press the MENU button to enter the system configuration settings.
- Turn the ADJUST Knob to select TONE_MODE setting.
- The cursor will flash at the beginning of this menu option.
- Press MENU button again to move the flashing cursor to the setting position.
- Turn the ADJUST knob to change the TONE_MODE setting between MUTE or 1KHZ.
- Press the ADJUST knob in to save or confirm the chosen setting.
- The flashing cursor will return to the beginning of this menu option.
- Rotate the ADJUST knob to choose another menu option or press the mode button.
N.B. The MUTE value will silence the test tone but will not restore any audio source being fed into the AD-
100. Please set the TONE_OUT menu option to OFF to switch back to an audio input source instead.

6. TONE_LEVEL

This setting adjusts how loud or quiet the test tone will be at the output. +26dBu=VERY Loud and -34dBu=Quiet.
- Press the MENU button to enter the system configuration settings.
- Turn the ADJUST Knob to select TONE_LEVEL setting.
- The cursor will flash at the beginning of this menu option.
- Press MENU button again to move the flashing cursor to the setting position.
- Turn the ADJUST knob to select the TONE_LEVEL setting value from +26 ~ - 34 dBu.
- Press the ADJUST knob in to save or confirm the chosen setting.
- The flashing cursor will return to the beginning of this menu option.
- Rotate the ADJUST knob to choose another menu option or press the mode button.
8

Advertisement

Table of Contents
loading

Table of Contents