Touch Screen Calibration

To calibrate the touch screen perform the following steps.
1.
The oven must be plugged In.
2.
Stand-by screen must be in the Display.
3.
Press the Hidden Pad.
4.
Press Pads 4, 5, 6.
5.
Press Directly ON small Square in the Display.
The Square will move to a different location on the Display.
6.
Press Directly On the small Square in the Display again until the
square disappears
7.
Press the 0 Pad.
8.
A small box will appear in the top left square. Press on each box
and the small square will follow. After you have touched all the boxes
and the small square followed you go to step 9.
9. Press the 0 pad to return to the Stand-by screen.
Note: If the small square did not follow you to each square repeat each square.
Calibration
Standby Screen
Type a
Hidden Pad
.
29
Type b